LECTROSONICS, INC.

8

Operating Instructions

Power Up and Boot Sequence

Simultaneously press and hold the AUDIO and FREQ

buttons until the startup count is completed. The

screen will display a count from 1 to 3 as the unit boots

up, then it switches to the Audio screen. As the unit

turns on, the Modulation LEDs and PWR LED all glow

red, then green, and then revert to normal operation.

The LCD displays a boot sequence which consists of

four screens ending with the audio screen similar to

this example:

• Company name:

Lectro

• Frequency block/Firmware Ver.: b21r1.1

• Power level:

Pr 100

• Compatibility mode:

CP 400

• Audio (Input gain):

Aud 22

Power Down

Simultaneously press and

hold the AUDIO and FREQ

buttons while observing that

the word “OFF” appears in the LCD along with a

counter. The screen will display a countdown from 3 to

1 and the unit will then turn off.

Note: If the AUDIO and FREQ buttons are

released before the LCD goes blank at the end of

the countdown, the unit will not turn off. Instead,

it will stay energized and the display will return to

the previous screen.

Standby Mode

Quickly press both AUDIO

and FREQ buttons to enter

the “standby” mode. In this

mode the RF output is turned off so adjustments can

be made without interfering with other systems operat-

ing in the same location. The LCD displays

rf OFF to

remind you that the unit is not transmitting.
Use the AUDIO and FREQ buttons to access the vari-

ous setup screens. When the adjustments are com-

plete, press both the AUDIO and FREQ buttons briefly

to save the settings and turn the unit off.

Compatibility, Output Power, Bias Voltage

(phantom power) and LCD Backlight

Four different setup screens are accessed in a setup

mode that is accessed with a special button sequence.

• Compatibility Mode

• Output Power

• Bias Voltage (phantom power)

• LCD Backlight Settings

Hold the UP arrow button and simultaneously press

the AUDIO and FREQ buttons. The compatibility setup

screen will appear. Each successive press of the

AUDIO button will step through the other three setup

screens.

Then press the AUDIO and FREQ

buttons at the same time

Hold the UP

arrow button

Note: The unit is automatically set to “standby” in

this setup mode, however, the

rF OFF reminder

will not be displayed.

Compatibility Mode

In addition to its native Digital Hybrid mode, the trans-

mitter will operate with Lectrosoncs 100 Series, 200

Series and IFB receivers, as well as several analog

receivers from other manufacturers.

From this screen, use the

UP and DOWN arrows to

select the desired mode.

CP 100: 100 Series mode

CP 200: 200 Series mode

CP 3: Mode 3 (contact the factory for details)

CP 400: 400 Series mode

CP IFB: IFB Series mode

CP 6: Mode 6 (contact the factory for details)