Troubleshooting specifications, Symptom, Possible cause – Lectrosonics PA8 User Manual

Page 6

Advertising
background image

PA8

6

Troubleshooting

Specifications

Line Input
Type:

Electronically balanced and RF

filtered

Impedance:

20k Ohms, Balanced or

Unbalanced

Input Level for Rated Output:

-2dBu (615mVRMS) at maximum

level

+15dBu (4.36VRMS) at mid level

Output Power:

10 Watts into 4 Ohms, 6 Watts into

8 Ohms

20 Watts into 8 Ohms with bridged

monoconfiguration

Output impedance:

4 Ohms minimum

Maximum System Gain
Line Input to Speaker Out:

20dB (x10)

SYMPTOM

No sound from system

POSSIBLE CAUSE

1) Channel Level control not turned up

2) Channel input incorrectly wired

3) Power switched off

4) Fuse may be blown

Signal-to-Noise Ratio:

88dB relative to 10W at 4 Ohms

System THD:

Less than 0.1%, 20Hz to 20kHz

(10W into 4 Ohms)

System IMD:

Less than 0.1%, 60Hz/7kHz (10W

into 4 Ohms)

Slew Rate:

12V/uS

Power Consumption:

200 Watts max at 120VAC

Euro Version*:

200 Watts max at 230VAC

Weight:

8 lbs, 9 ozs

Dimensions:

19” wide x 1.3/4” high x 8 1/4” deep

*

Euro version, I-PA8 is CE marked and runs on 220VAC.

Specifications subject to change without notice

Advertising