lCr-II MoUnTInG

LC Meter

O-Ring

Lower register

and bolt down

Insert cotter

pin

Place shaft

adapter on

drive shaft

LectroCount LCR-II

Gallons

LCR-II Bolt Pattern

LC Meter Compensated

LC Meter

Mounting bolt Pattern

The LectroCount LCR-II base casting contains eight bolt

holes in an industry standard bolt pattern. The holes are

½" deep and take ¼"-20 screws.

If the installation necessitates that you fabricate a

bracket, refer to the drawing to the right.

lC Meters

remove existing registration equipment

1. Depressurize the meter completely. See Warning on pg.

14.

2. Remove the four bolts on the bottom that fasten the

register to the meter.

3. Remove the adjuster from the meter.
4. If the meter has a Temperature Volume Compensator

(TVC), remove it as well.

Mount the lectroCount lCr-II

1. Place the end of the shaft adapter on the pulser drive

shaft located on the bottom of the register.

2. Place the cotter pin through the hole, and bend open the

ends of the cotter pin.

3. Lower the register onto the meter, and insert the shaft

adapter onto the hex shaft on the meter.

4. Securely bolt down the register.

Apply anti-seize to all bolt threads to ensure

easy removal at a later date.