Lightronics FXLD1018FRP5I User Manual

Lightronics Lighting

Advertising
background image


Page

1

of

6

FXLD1018FRP5I LED FIXTURE

Version 0.1 OWNERS MANUAL 07/08/2013

www.lightronics.com

Lightronics

Inc.

509

Central

Drive

Virginia

Beach,

Va

234354

757

486

3588

FEATURES AND SPECIFICATIONS

LEDS: 18, 10W each (RGBWA, 5 in 1)
White LED Color Temperature: 6500K
Beam angle: 25 º
Control system: DMX-512 + Stand Alone Modes
DMX channels: 5/9
DMX connectors: 3 pin XLR and 5 pin XLR
Refresh Rate: >400 Hz)
Voltage: 120 - 240 VAC 50/60Hz
Max power consumption: 200 Watts
Cooling: Internal Fan
Body material: Die Cast Aluminum
Body color: Black
Size: 13.3"L x 11.81"W x 4.56"H (without brackets)
Weight: 16.5 lbs (7.5 kg)

DESCRIPTION

The FXLD1018FRP5I is a RGBWA LED lighting
fixture. It is suitable for stage, disco, night club, and
other artistic applications. It has several stand alone
control modes and can operate via a DMX-512
external signal.

A double yoke enables the fixture to be operated in
several positions.

INSTALLATION

LOCATION

The FXLD1018FRP5I is rated IP20 and is intended for

INDOOR USE ONLY.

Locate the unit in a well ventilated area away from
moisture and heat. Keep the vent holes clear. Holes
are provided on the yokes to install a lighting bar pipe
clamp. Use a safety cable when hanging the fixture.

POWER CONNECTIONS




The FXLD1018FRP5I has a blue powercon style
connector for power input. A compatible power cable
is provided for connection to a 120 VAC, 15 Amp,
60Hz, grounded service. Push the blue connector on
the cable straight into the blue connector on the unit
and twist aprox. 1/8 turn clockwise to latch it.
























The white powercon style connector on the unit is used
to pass power on to another FXLD1018FRP5I unit. A
mating white connector is also provided.

Caution is advised since the line cord is rated for
aprox. 7 Amps maximum.

THE SAFETY GROUND TERMINAL ON THE POWER
CABLE MUST BE USED.

DMX CONNECTIONS

A system using DMX control should be connected as a
chain of devices. In other words the control signal
cable should proceed from the controller to the first
receiving device and then to others in a continuous
"daisy chain" fashion.

The fixture has a DMX IN and a DMX OUT connector
to be used to connect the chain. The control cable
should NOT be split into a multiple run star
arrangement with a cable running from the controller
directly to each receiving device pack.



CAUTION

RISK OF ELECTRIC SHOCK

Advertising