Lightronics AS62L User Manual

As-62l compact dimmer

Advertising
background image


www.lightronics.com

Lightronics Inc.

509 Central Drive, Virginia Beach, VA 23454

Tel: 757 486 3588








OWNERS MANUAL

Version 0.1 02/14/2005

Page 1 of 6

AS-62L

COMPACT DIMMER





IMPORTANT:

Please take a moment to read this manual

before operating the AS-62L Dimmer






DESCRIPTION

The AS-62L is a compact 4 channel light dimmer. It has a maximum capacity of 1200 Watts per channel and
maximum total load capacity of 4800 Watts. It is supplied with 2 input power cord stubs which may be connected
to 2 different 120 VAC power phases. The AS-62L is intended for INDOOR USE ONLY. The unit operates using
the industry standard three wire multiplex protocol. The AS-62L may be operated in a relay (non-dim) mode. The
unit will also function as a chaser and has several preset chase patterns which may be used.

INSTALLATION

LOCATION: Locate the unit in a well ventilated area away from moisture and heat. Two ½” holes are provided
on the dimmer top cover to install a lighting bar pipe clamp and a suitable safety cable.

POWER CONNECTIONS: Extending from the chassis are two 20 amp line cords for connection to 2 separate
120 VAC, 20 Amp, grounded services in any phase combination. Total capacity of the AS-62L is 4800 Watts.

LOAD CONNECTIONS: There are 6 numbered duplex outlets on the top of the unit. Each provides 2
connections for one of the output channels. You can connect up to 1200 Watts of lighting to a single channel.
The total load capacity of the AS-62L channels 1, 3, and 5 combined is limited to 2400
Watts. The total load capacity of the AS-62L channels 2, 4, and 6 combined is also limited
to 2400 Watts.

CONTROL SIGNAL CONNECTIONS

The male three pin XLR connector on the unit end panel connects to the control console. The female connector
is for connection to additional dimmers. The AS-62L dimmer LMX-128 protocol is compatible with the Lightronics
and NSI/Sunn three wire multiplexed protocol. If you have older Lightronics dimmers which run in the obsolete
Lightronics mode only, contact Lightronics for information on changing the mode. When using multiple dimmers,
ALL dimmers MUST be in the SAME mode.

CONTROL SIGNAL WIRING:

Connector Pin #

Signal Name

1 LMX

Common

2 Console

Power

3 Multiplex

Signal


Advertising