TL – 4016 MEMORY CONTROL CONSOLE

Revision 1.4

OWNERS MANUAL

02/20/2005

www.lightronics.com

Lightronics

Inc.

509

Central

Drive

Virginia

Beach,

VA

23454

TEL

757

486

3588


DMX OPERATION

If the DMX option is installed in the TL-4016 then it will transmit both DMX and LMX signals simultaneously.
The DMX-512 connection does NOT provide console power therefore an external power supply (provided with
units having DMX option) must be used.

QUICK START INSTRUCTIONS

The bottom cover of the TL-4016 contains brief instructions for using scenes and chases. The instructions are not
intended as a substitute for this manual and should be viewed as "reminders" for operators who are already
familiar with TL-4016 operation.

MAINTENANCE AND REPAIR

TROUBLESHOOTING

Check that the multiplex cable is not defective.
To simplify troubleshooting - reset the unit to provide a known set of conditions.
Make sure that the dimmer address switches are set to the desired channels.

OWNER MAINTENANCE

The best way to prolong the life of your TL-4016 is to keep it dry, cool, clean and covered when not in use.

The unit exterior may be cleaned using a soft cloth dampened with a mild detergent/water mixture or a mild spray-
on type cleaner. DO NOT SPRAY ANY LIQUID directly on the unit. DO NOT IMMERSE the unit in any liquid or
allow liquid to get into the controls. DO NOT USE any solvent based or abrasive cleaners on the unit.

The faders are not cleanable. If you use a cleaner in them – it will remove the lubrication from the sliding
surfaces. Once this happens it is not possible to re-lubricate them.

The white strips above the faders are not covered by the TL-4016 warranty. If you mark on them with any
permanent ink, paint etc. it is likely that you will be unable to remove the markings without damaging the strips.

There are no user serviceable parts in the unit. Service by other than Lightronics authorized agents will void your
warranty.

EXTERNAL POWER SUPPLY INFORMATION

The TL-4016 may be powered by an external supply with the following specifications:

Output Voltage: 13 to 25 Volts AC or DC

Output

Current:

400

Milliamps

Connector:

2.1mm

female

connector


NOTE: If a DC Supply is used – the center pin must be the NEGATIVE voltage.

OPERATING AND MAINTENANCE ASSISTANCE

Dealer and Lightronics Factory personnel can help you with operation or maintenance problems. Please read the
applicable parts of this manual before calling for assistance.

If service is required - contact the dealer from whom you purchased the unit or contact Lightronics, Service
Dept., 509 Central Drive, Virginia Beach, VA 23454 TEL: (757) 486-3588.

Advertising