SPECIFICATIONS

Battery: 2 each AA alkaline batteries

included

(see battery replacement section)

ABOUT THE MEMORY

Minimum and maximum memories are

NOT programmable (see Alarms).

The minimum humidity, temperature, and dew-point

recorded into memory are the minimum humidity,

temperature, and dew-point achieved since the

last time the memory was cleared. The maximum

humidity, temperature, and dew-point recorded into

memory are the maximum humidity, temperature,

and dew-point achieved since the last time the

memory was cleared. The minimum and maximum

memories are maintained over the period since the

memory was cleared.
VIEWING THE MIN/MAX MEMORY

To view the maximum humidity, temperature, and

dew-point memory, press the MIN/MAX button once

on the side of the unit. The maximum humidity,

temperature, and dew-point reading achieved will be

displayed (“MAX” will appear on the display).

Press the MIN/MAX button a second time, within

16 seconds, to view the minimum humidity,

temperature, and dew-point achieved (“MIN” will

appear on the display).
Note: Sixteen (16) seconds after pressing the MIN/

MAX button, the unit automatically returns to the

current humidity, temperature, and dew-point reading.
Press the MIN/MAX button a third time, within

16 seconds, to return to the current humidity,

temperature, and dew-point reading.
CLEARING THE MAXIMUM MEMORY

The maximum humidity, temperature, and dew-point

memory may be cleared. To clear the maximum

memory, press and hold the RESET button on the

side of the unit while the maximum memory value

is being displayed (see the “Viewing the Memory”

section). The display will show “- -” for approximately

5 seconds and will then display the current reading.
CLEARING THE MINIMUM MEMORY

The minimum humidity, temperature, and dew-point

memory may be cleared. To clear the minimum

memory, press and hold the RESET button on the

side of the unit while the minimum memory value

is being displayed (see the “Viewing the Memory”

section). The display will show “- -” for approximately

5 seconds and will then display the current reading.
SELECTING °C OR °F

To display the temperature/dew-point reading in

Fahrenheit or Celsius, slide the °C/°F switch, located

on the back of the unit, to the desired position.
ALARMS

Alarm may be set for humidity only within the range

of three RH values 55%, 60% and 65%. To set the

unit to alarm when the ambient humidity increases

to 55% RH and above, slide the switch located on

the back of the unit to 55%. To set the unit to alarm

when the ambient humidity increases to 60% RH and

above, slide the switch located on the back of the unit

to 60%. To set the unit to alarm when the ambient

humidity increases to 65% RH and above, slide the

switch located on the back of the unit to 65%.
VISUAL ALARM INDICATOR

The unit will visually indicate an increase in ambient

humidity above set alarm points when the switch

located on the back of the unit is set to AL. OFF. A

red LED on the front of the unit will flash if conditions

rise above a set alarm point. When the ambient

conditions fall below the set alarm point the LED will

no longer flash.

AUDIBLE ALARM INDICATOR

To set the unit to audibly alarm at set points. Slide the

switch located on the back of the unit to AL. ON. An

alarm will sound and the LED will flash if the current

ambient humidity is above the set alarm point. When

ambient conditions fall below the set alarm point, the

audible alarm will no longer sound and the LED will no

longer flash.
WALL MOUNTING THE UNIT

Set a screw into the wall at the desired location. Do

not set the screw flush to the wall, the head of the

screw will need to slip into the receptacle on the back

of the unit. Once the screw has been properly set,

hang the unit in place by sliding the receptacle on the

back of the unit over the head of the screw.
USING THE SUPPLIED

BENCH STAND

When standing the unit on

a desk or lab bench, use the

supplied BENCH STAND

(see Fig 1).
Place the stand on the desk

and affix the unit as shown.

Fig 1.