Control Company 5043 TRACEABLE TIE TIMER User Manual

Traceable, Tie timer instructions, Control company

Advertising
background image

Traceable

®

is a registered trademark of Control Company ©2007 Control Company. 92-5043-00r2 122707


SPECIFICATIONS
Display:

½”-high 6-digit LCD

Range:

24 hours to 1 second

Resolution: 1 second
Accuracy: 0.01%
Alarm:

Audible

Size:

1⅛” x 2-7/16”

Weight:

Less than 1 oz.

Features: Clock, Countdown/Countup

Stopwatch, Memory

CONTROLS/INDICATORS
Clock – Sets time of day
Count Up – Stopwatch mode
Timer – Countdown from preset time.
HR – Advances hour setting when in the clock mode.
MIN – Advances minute setting when in the clock mode.
SEC – Advances second setting when in the clock mode.
CLEAR – Clears all time values, memory settings and returns the display to zero.
MEMORY – Sets time value for recall.
START/STOP – Starts and stops timing function in countup and timer modes.

OPERATION
TIMING MODES
The red switch located on the bottom of the unit will switch the timing between
“Clock”, “Countup” (stopwatch) and “Timer” mode.

SETTING TIME-OF-DAY
1. Slide the red switch to “CLOCK” position.
2. Press and hold the “CLEAR” button for 3 seconds to toggle the display

between 12-hour and 24-hour format.

3. Press the “HR”, “MIN”, or “SEC” button to advance display to the desired time.

Press and hold the button for rapid advancement.


COUNT-UP
1. Slide CLOCK/COUNT-UP/TIMER switch to COUNT-UP position.
2. Press START to start counting up.
3. To temporarily stop timing, press STOP.
4. Press START to restart.
5. If Count-up is already counting, press START/STOP to stop count-up.
6. Press CLEAR to reset digits to 0:00:00.

SETTING TIMER
1. Slide the CLOCK/COUNT-UP/TIMER switch to TIMER




2. If Timer is already running, press START/STOP to stop and then CLEAR to

clear entry.

3. Press and hold each of the HR, MIN or SEC buttons to set the desired time.
4. Press START. Timer will start counting down. When the set time limit is

reached the Alarm will sound, the Time’s Up indicator will flash and Timer will
count up from “0:00:00” to indicate elapsed time since the alarm sounded.
The “TIMER” indicator will flash while in Clock or Count-up mode to indicate
the Timer is running.

5. To completely or temporarily stop timing cycle, press STOP. To restart, press

START.

6. To clear entry, press CLEAR. If Timer is running, press STOP first.
7. When in Clock mode or Count-up mode, stop the alarm by pressing STOP.
8. To stop the alarm and stop and clear the “TIME’S UP” count up, select Timer

mode and press STOP.


MEMORY
1. Select Timer mode. Press memory to see if an entry is already stored in

“MEMORY”, press CLEAR to return display to “0:00:00”.

2. If the timer is running, press START/STOP to stop. Depress each of the HR,

MIN or SEC buttons to set the desired time and press MEMORY to enter the
preset time. The MEMORY indicator will only show on the display in Timer
mode when memory button is depressed.

3. Press START. Timer will start count-ing down. When the set time limit is

reached the Alarm will sound, the Time’s Up indicator will flash and Timer will
count up from “0:00:00” to indicate elapsed time since the alarm sounded.

4. Press START/STOP to stop count-up.
5. Press MEMORY to recall preset time.
6. Press CLEAR to cancel preset time or press START/STOP to begin

countdown again.


ALL OPERATIONAL DIFFICULTIES
If this unit does not function properly for any reason, replace the battery with a
new high-quality battery (see “Battery Replacement” section). Low battery power
can occasionally cause any number of “apparent” operational difficulties.
Replacing the battery with a new fresh battery will solve most difficulties.

BATTERY REPLACEMENT
Erratic readings, a faint display, no display, or a flashing display are all indicators
that the battery must be replaced. Slide the battery compartment panel (located
at the back of unit) in the direction indicated. Replace exhausted battery with a
new battery and secure the battery compartment panel. Replacement battery Cat.
No. 1039.

WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:

CONTROL COMPANY

4455 Rex Road

Friendswood, Texas 77546 USA

Ph. 281-482-1714 Fax 281-482-9448

E-mail [email protected]

www.control3.com

Control Company is ISO 9001 Quality-Certified by DNV

and ISO 17025 accredited as a Calibration Laboratory

by A2LA.

Traceable

®