Electric Supply

The wiring must be done by a qualified electrician in accordance with local electrical codes. A separate
ground wire must be supplied for all installations.

A properly wired refrigerator or freezer will assure proper operation. Please consult the “Data” plate
attached to the compressor for the correct electrical requirements. Supply voltage requirements are on
the cabinet serial plate.

It is recommended that a direct, properly fused line of the proper size wire be installed from the main
supply to your refrigerator or freezer. It is most important that a voltage reading be made at the
compressor motor electrical connections, or as close to the compressor motor as possible at start-up and
while the refrigerator or freezer is in operation, to insure that the correct voltage required by the
compressor is being supplied.

Low or high voltage can detrimentally affect the refrigeration unit and thereby void its warranty.

G.

Installation Check List

After the cabinet has been installed, leveled and cleaned as described in the preceding paragraphs, refer
to the following check list prior to start-up.

°

Full voltage of the correct type, on a line not affected by the operation of other electrical
appliances, must be available at the condensing unit junction box during operation. Condensing
units are designed to operate with a voltage fluctuation of plus or minus 10% of the voltage
indicated on the cabinet electrical data plate. Burnout of a condensing unit due to exceeding the
high or low voltage limits will void the factory warranty.

°

Check all refrigeration lines to make sure they are not severely dented, kinked or rubbing.

°

Check condenser fan for freedom to rotate without striking any stationary members.

°

Cabinet must be properly leveled.