Section 3 - Plumbing Installation

QUESTIONS?... Contact Customer Service at 1-800-753-1601 M-F 8:00 am- 4:30 pm CST

9

3/8" Copper Tube

To tee assembly

on pump

P/N 8917

Brass Elbow

3/8" comp x 1/4 NPT

FIGURE 8

PLUMBING INSTALLATION - To Burner

1. Attach the 3/8" comp x 1/4" NPT brass elbow (P/N

8917) as indicated in Fig 8.

2. Install the remaining 3/8" copper tube between

3. Assemble a 1/2” close nipple (P/N 8186, 1/2” x 1/4”

reducing coupling (P/N 8558), and 3/8” comp x
1/4” MPT brass elbow (P/N 8917). Install this assembly
into the 1/2” bung on the top of the tank. Connect a
3/8” copper tube from the relief valve on the metering
pump to the assembly described above (see Fig 3 & 8).

the compression fittings of the by-pass regulator
and burner (see Fig 8).
NOTE: Make sure all fittings are properly tight-
ened. Leaking fittings may cause delayed ignition
in the burner.

Tank Drain and Plug

1. Determine which side of the tank the drain will be on. On that side, install a 1/2" close nipple

(P/N 8186) to the drain hole (see Fig 9).

2. Install the 1/2" brass ball valve (P/N 8187) to the 1/2" close nipple. Install a 1/2" pipe plug (P/N 8185)

into the end of the ball valve (see Fig 9).

3. Install a 1/2" pipe plug (P/N 8185) into the hole on the opposite side of the tank (see Fig 10).

4. Vent the tank in accordance to state and local codes.

FIGURE 9

FIGURE 10

P/N 8186
1/2" Close Nipple

P/N 8187

1/2" Brass Ball

Valve

P/N 8185

1/2" Pipe Plug

P/N 8185
1/2" Pipe Plug