11-3.

Jog movement direction and coordinate system

(1) Jog keys and movement directions

The movement direction during jog operation changes according to the coordinate system No.

selected.

The status before shipment is the base coordinate system (work coordinate system No. 0)

and tool coordinate system No. 0.

For the setting of coordinate system data, refer to “13. Coordinate System Data Editing.”


Jog movement on base coordinate system

The jog keys and movement directions on the base coordinate system are as shown below.




The current position display on the teaching screen
is the position on the work coordinate system
selected.
When the tool coordinate system No. is also
selected, the coordinate value of the tool tip position
is applied.

Jog movement on base coordinate
system (work coordinate system No.
0)

Left arm system

To change the coordinate system for
jog operation, press the F4 (JCrd)
key.

To switch between the input data
screen and the current position
display, press the F1 (Disp) key.

49