6.5. Alignment aid function

SG4-B light curtain is fitted with a system which informs the user
about reached alignment degree. The alignment function can be
selected on device starting by keeping closed RESET/RESTART
N.O. contact for at least 0.5 seconds (Fig.24).

Alignment mode timing

OFF

ON

RESET

STATO DELLA BARRIERA

0Vdc

24Vdc

0.5 s

ON

OFF

STATO DELLA BARRIERA ( ALLINEAMENTO )

Fig. 24

Once optimal alignment has been reached, the device can return to
normal functioning by powering off and then powering on the RX unit.

The alignment level is monitored also during device normal operating
mode via display (see paragraph 7.2). Once the curtain has been
aligned and correctly fastened, the display signal is useful to check
the alignment and view any change in the environmental conditions
(presence of dust, light disturbance and so on).

NOTE: OSSDs are not enabled on alignment mode.