Operation and Maintenance Manual for Joyce/Dayton

Rotary Limit Switch Model LS8-402

DESCRIPTION:
This rotary limit switch is designed to control the limits of travel of rotating reversing equipment.

The limit switch input shaft is connected to a worm gear. Adjustable self-lubricating nylon roller
cams are concentrically mounted to the worm gear. These adjustable cams actuate either single
pole double throw (S.P.D.T.) or double pole double throw (D.P.D.T.) precision limit switch units.

CAUTION: DISCONNECT ELECTRICAL POWER BEFORE REMOVING COVER.

DANGER OF SEVERE ELECTRICAL SHOCK.

A

B

1B

1A

S.P.D.T.

D.P.D.T.

2A

2B

B

A

Electrical Contact Ratings

Volts

Contacts

Make & Break Amperes

AC

DC

SPDT

DPDT

110

220
440
600

15
15
15
15

0.25
0.1

-
-

115

230
440
575

10
10
10
10

0.2
0.1

-
-