Installation, Pad mounting, Arm fabrication – LiftMaster BG770 Industrial-Duty Single Arm Barrier Gate Operator User Manual

Page 6: Calculate arm length

Advertising
background image

6

PAD MOUNTING

1. Layout the concrete pad (Figure 2). Be sure to locate electrical

conduit inside the hatched 14" x 13" area.

2. Excavate required area for pad and conduit. Pad depth should

be below the frost line or as required by local codes.

3. Pour concrete pad. Concrete pad should be level and above the

ground line.

4. Allow the concrete to set at least two days before installing

operator.

5. Secure operator with four concrete anchors (not provided).

ARM FABRICATION

MODEL BG770 (SINGLE ARM)

If you are making the arm yourself, refer to Figure 3 and its
suggestions for the single arm design.

1. Drill four 1/2" diameter holes using the arm clamp as a

template. Tapering the wood as shown helps reduce the
weight and allows you to reduce any warping common
with long lengths of lumber.

2. Cut to desired length. Refer to Calculate Arm Length below.

3. Finish arm with exterior grade paint and stripe with paint or

adhesive backed tape as required.

MODEL BG790 (WISHBONE ARM)

A 24' wishbone arm is provided as standard with every BG790
gate. If a shorter arm is desired, the extension may be shortened
(Figure 4). The maximum arm extension is 8' for a total arm
length of 24'.

1. Cut to desired length. Refer to Calculate Arm Length below.

2. Finish with an exterior grade paint and stripe with paint or

adhesive backed tape as required.

I N S T A L L A T I O N

Figure 3

Material:
6: x 1" Pine or Redwood

Length as needed
up to 12'

3"

5-12"

Figure 2

12"

14"

20"

14-1/2"

Conduit Entry Area

Arm

13"

22"

Material:
4: x 1" Pine or Redwood

Arm Extension

Length up to 8'

Figure 5

CALCULATE ARM LENGTH

To calculate the arm length:

Subtract the height of the output shaft and concrete pad (40")
from the height to ceiling (see Figure 5).

EXAMPLE:

If height to ceiling is 8'3" (99"), calculation is as follows:

99" (height to ceiling) - 40" (height of the output shaft and
concrete pad)
= 59"

Lower arm should be 59".

Figure 4

Height to
ceiling

Arm length

Output Shaft

Arm

Height of the
output shaft and
concrete pad (40")