Installation, Install the kpr2000, Choose an operation mode – LiftMaster KPR2000 Single Entry Access Control Keypad and Proximity Reader User Manual

Page 3

Advertising
background image

3

INSTALLATION

1

2

3

4

5

6

7

8

9

*

0

#

STAND ALONE OPERATION

The KPR2000 functions as a complete access control system. The user
database is stored in non-volatile memory, reads the PINs and card
codes, performs the authentication, and grants and monitors access to
the property or device. In Stand Alone Operation there are three different
Access Configurations listed below:

• Card or PIN (Default): The User must present a valid Wiegand Card to

the KPR2000 or enter their PIN code followed by the # key, in order to
be granted access.

Card

Only: The User must present a valid Wiegand Card to the

KPR2000 in order to be granted access. The facility code and the ID
number are both read and validated as one block of Wiegand data.

• Card + PIN: The User must first present a valid Wiegand Card to the

KPR2000 and then enter their PIN code followed by the # key, in order
to be granted access.

1

Install the KPR2000.

2

Choose an Operation Mode.

PASS-THROUGH OPERATION

The KPR2000 passes all keypad and card reader Wiegand data to an
external controller. The KPR2000 should be in the “Card or PIN” access
configuration for pass-through operation.

IMPORTANT NOTE: Both modes of operation support Auto User ID
generation (simplest method) and manual entry of user ID.

Advertising