Please follow these easy steps to adjust the
pressure:

Step 1:

Remove black cap (pos. #1) from knob.

Step 2:

Loosen bolt (pos. #2) with 6mm hex
wrench.

Step 3:

Loosen nut (pos. #3) to top of (pos. #2)
bolt.

Step 4:

Turn the black knob (pos. #4) clockwise
until it stops.

Step 5:

Start machine hold trigger on open
position and turn (pos. #2) bolt

until no further increase of pressure is
noticed, continue to hold

trigger open and turn counter-
clockwise until a slight drop in

pressure is felt.

Step 6:

Spin (pos. #3) nut down. While holder
(pos. #2) bolt

in place with hex wrench, use special
tool (AR1560590)

Or extended 13mm socket wrench to
hand tighten

(pos. #3) nut against (pos. #4) black
knob.

Instructions for Adjusting Gymatic Unloader Valves

4

3

2

1

AR1560590

Nut holder for adjusting Gymatic Unloader

Mounting Bolt Torque Specifications
Inlet

354 in/lbs 30 ft/lbs

Discharge

221 in/lbs 19 ft/lbs

Step 7:

Replace (pos. #1) black cap.

NOTE:

Now pressure can be decreased by

turning black knob (pos. #4) counterclockwise,
but the pressure cannot be increased to a rating
higher than what max is set at by technician.