Performance, Pump specs – Versa-Matic 1 Elima-Matic Bolted Metal – Food Processing (E1 ) User Manual
Page 6
e1mdlCsmFP-rev0314
www
.
versamatic
.
com
3
• Model E1 Metallic Bolted
Performance
E1 1" Bolted Metal
Rubber and TPE Fitted
Flow Rate
Adjustable to . . . . . . . 0-46 gpm (174.1 lpm)
Port Size
Suction . . . . . . . . . . . . . . . 1½" TRI-CLAMP
Discharge. . . . . . . . . . . . . 1½" TRI-CLAMP
Air Inlet . . . . . . . . . . . . . . . . . . . . . . 3/8" NPT
Air Exhaust . . . . . . . . . . . . . . . . . . 1/2" NPT
Suction Lift
Dry . . . . . . . . . . . . . . . . . . . . . . . .16' (4.9 m)
Wet. . . . . . . . . . . . . . . . . . . . . . . .31' (9.4 m)
Max Solid Size (Diameter)
. . . . . . . . . . . . . . . . . . . . . . . . 1/8" (3.2 mm)
Max Noise Level . . . . . . . . . . . . . 93 dB(A)
Shipping Weights
Stainless Steel . . . . . . . . . . .36 lbs (16.3 kg)
E1 1" Bolted Metal
PTFE Fitted
Flow Rate
Adjustable to . . . . . . . 0-36 gpm (136.3 lpm)
Port Size
Suction . . . . . . . . . . . . . . . 1½" TRI-CLAMP
Discharge. . . . . . . . . . . . . 1½" TRI-CLAMP
Air Inlet . . . . . . . . . . . . . . . . . . . . . . 3/8" NPT
Air Exhaust . . . . . . . . . . . . . . . . . . 1/2" NPT
Suction Lift
Dry . . . . . . . . . . . . . . . . . . . . . . . .11' (3.4 m)
Wet. . . . . . . . . . . . . . . . . . . . . . . .31' (9.4 m)
Max Solid Size (Diameter)
. . . . . . . . . . . . . . . . . . . . . . . . 1/8" (3.2 mm)
Max Noise Level . . . . . . . . . . . . . 96 dB(A)
Shipping Weights
Stainless Steel . . . . . . . . . . . . .36 lbs (16.3 kg)
NOTE: Performance based on the following: PTFE fitted pump, flooded suction, water at ambient conditions.
The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.
NOTE: Performance based on the following: elastomeric fitted pump, flooded suction, water at ambient conditions.
The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.
0
20
40
60
80
100
120
140
Discharge Head in PSI
Meters Feet
240
220
200
180
160
140
120
100
80
60
40
20
0
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
1
3
2
4
5
6
7
BAR
Capacity in Liters Per Minute
Capacity in U.S. Gallons Per Minute
Capacity Per Stroke: 0.047 Gal (0.18 L)
0
20
40
60
80
100
0
5
10
15
20
25
30
35
40
5 10
20
30
AIR CONSUMPTION IN SCFM
AIR PRESSURE IN PSI
SCFM M3/HR
5
8.5
10
17
20
34
30
51
0
20
40
60
80
100
120
140
160
180
Discharge Head in PSI
Capacity in Liters Per Minute
Capacity in U.S. Gallons Per Minute
0
20
40
60
80
100
0
5
10
15
20
25
30
35
40
45
50
5
10
20
30
Meters Feet
240
220
200
180
160
140
120
100
80
60
40
20
0
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
1
3
2
4
5
6
7
BAR
AIR CONSUMPTION IN SCFM
AIR PRESSURE IN PSI
SCFM M3/HR
5
8.5
10
17
20
34
30
51
Displacement Per Stroke, .09 Gal. (0.34 L)
1: PUMP