Rooftop packaged unit with evaporative cooling, Table 2a – Sterling EV User Manual

Page 4

Advertising
background image

4

Rooftop Packaged Unit

with Evaporative Cooling

Figure 3 - Natural Vent Rooftop Unit with Evaporative Cooler (without Supply Plenum)

A.G.A.

C.G.A.

GAS

INLET

CAPACITY

A B C D D *F G

J L §U

NAT LP

10

32-7/8 15-9/16 12

11 20-11/16 19-3/8 31-1/16 24

77-3/8 72-1/4

1/2

1/2

(835) (395) (305) (279) (525) (492) (789) (610) (1965)

(1835)

15

32-7/8 18-5/16 21-1/2

16 25-3/16 23-1/2 31-1/16 24

77-3/8 72-1/4

1/2

1/2

(835) (465) (546) (406) (640) (597) (789) (610) (1965)

(1835)

20

43-7/8 23-13/16 23-1/2

16

25-3/16 26-1/4 42-1/16

35

77-3/8 72-1/4

1/2

1/2

(1114) (605) (597) (406) (640) (667) (1068) (889) (1965)

(1835)

25

43-7/8 29-5/16 23-1/2

16 25-3/16 34-1/2 42-1/16 35

77-3/8 72-1/4

3/4

1/2

OR

3/4

(1114) (745) (597) (406) (640) (876) (1068) (889) (1965)

(1835)

30

54-7/8 34-13/16 26

17-1/2 26-11/16 37-1/4 53-1/16

46

77-3/8 72-1/4

3/4

1/2

OR

3/4

(1394) (884) (660) (445) (678) (946) (1348)

(1168)

(1965)

(1835)

35

54-7/8 40-5/16

26

17-1/2 26-11/16 45-1/2 53-1/16

46

77-3/8 72-1/4

3/4

1/2

OR

3/4

(1394) (1024) (660) (445) (678) (1156) (1348) (1168) (1965) (1835)

40

60-3/8 45-13/16 26

17-1/2 26-11/16 51

58-9/16 51-1/2 77-3/8 72-1/4

3/4

1/2

OR

3/4

(1534) (1164) (660) (445) (678) (1295) (1487) (1308)

(1965) (1835)

50

43-7/8 29-5/16 23-1/2

16 25-3/16 34-1/2 42-1/16 35 103-3/8 98-1/4

3/4

1/2

OR

3/4

(1114) (745) (597) (406) (640) (876) (1068) (889) (2626)

(

2496

)

60

54-7/8 34-13/16 26

17-1/2 26-11/16 37-1/4 53-1/16

46

103-3/8 98-1/4

3/4

1/2

OR

3/4

(1394) (884) (660) (445) (678) (946) (1348)

(1168)

(2626)

(

2496

)

70 54-7/8

40-5/16 26 17-1/2

26-11/16

45-1/2

53-1/16 46 103-3/8

98-1/4

3/4 1/2

OR

3/4

(1394) (1024) (660) (445) (678) (1156) (1348) (1168) (2626) (

2496

)

80

60-3/8 45-13/16 26

17-1/2 26-11/16 51 58-9/16 51-1/2 103-3/8 98-1/4

3/4

1/2

OR

3/4

(1534) (1164) (660) (445) (678) (1295) (1487) (1308) (2626) (2496)

NOTE: REFER TO UNIT SUBMITTALS FOR MORE SPECIFICATIONS/UNIT ARRANGEMENTS.

DIMENSIONS ARE IN INCHES, DIMENSIONS IN PARENTHESIS ARE IN MILLIMETERS.
* “F” DIMENSION IS THE RECOMMENDED CLEARANCE TO SERVICE THE BURNER DRAWER(S).

“J” DIMENSION IS AN OUTSIDE DIMENSION FOR RETURN AIR DAMPERS.

§ “U” ALL DIMENSIONS ARE TABULATED FOR ROOFTOP ARRANGEMENTS B & D PER CAPACITIES 10 THROUGH 80 ACCORDINGLY
(CAPACITIES 50/80 ARE SHOWN PICTORIALLY).
NATURAL VENT UNIT DIMENSIONS SHOWN ABOVE; FOR POWER VENT DIMENSIONS, CONTACT CUSTOMER SERVICE FOR POWER
VENT UNIT SUBMITTAL SHEETS.

Table 2A

D4163
T4160BD

B

Discharge

Opening

1-5/16" (33) Typ.
Anchor Hole
Location

5"

(127)

A

C (Typ. Sq.)

*

F

D

39"

(991)

G

Outside

1" (25)

Curb Cap

5/8" (16) Typ.
Anchor Hole
Location

6-1/16"

(154)

8-3/4
(222)

26"

(660)

Electrical
Connections

Vent Caps
Are Shipped
In Separate
Cartons

Gas
Connection

§ L

Evaporative
Cooler

18-7/8" (479)

x J Typ.

O.S. Damper

Opening

6-1/2"

(165)

36"

(914)

CL

1-1/8" (29)

Typ. Duct

Flange

1" (25)

Typ.

19"

(483)

Discharge

Opening

10-1/8"

(257)

§ U (Capacities 10/40)

§ U (Capacities 50/80)

36"

(914)

Advertising