DataComm 70-0070 10 Port Phone Module User Manual

Instruction / installation sheet

Advertising
background image

2/25/08 Rev. 1

Instruction / Installation Sheet

DataComm Electronics 10 Port 110 Style Punch-Down Telephone Module 70-0070

Installation

 Align the mounting pins with holes in the back of the HCC panel and lock module into

place.

 Install the cable from the telephone company demarcation point to the 110 IDC connector

marked from Telco.

 Install twisted pair cables from each location in the house to the remaining 110 IDC

connectors. Match the color-coding of the wires to the colors on the 110 IDC connectors.

 The wires should be punched down, using an industry standard punch-down tool, to the

110 IDC connectors following the T568A wiring configuration as shown below.

 The RJ31x port is used to install the security line.

 Line 1 is Blue, Line 2 is Orange, Line 3 is Green and Line 4 is Brown.

White / Blue

Blue

White / Orange

Orange

White / Green

Green

White / Brown

Brown

CAUTION

Never install telephone wiring during lighting storms.
Never install telephone jacks in wet locations unless the jack is specifically

designed for wet locations.

Never touch un-insulated wires or terminals unless the telephone line has been

disconnected at the network interface.

Use caution when installing or modifying telephone lines.

IMPORTANT INSTRUCTIONS

Read and understand all instructions.
Follow all warnings and instructions marked on the product.

Do not use this product near water, for example near a bath tub, wash bowl,

kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.

SAVE THESE INSTRUCTIONS.

ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT

DataComm Electronics, Inc.
6349 Peachtree Street
Norcross, GA 30071-1725
888.223.7977
770.662.8205
www.datacommelectronics.com

ETL LISTED

CONFORMS TO

UL STD 1863

ANSI/UL STD 60950-1

CERTIFIED TO

CAN/CSA STD C22.2 NO 60950-1