Pump inside tank option - close up, Unit – Davey RAINBANK WITH SUBMERSIBLE PUMP User Manual
Page 15

22
15
• Failure to prime the submersible
pump prior to connection of the pump
to rainbank
®
can cause an air lock
that may prevent the pump operating
properly.
The following sections of the Type
1 installation instructions are
applicable to Type 2 installations.
Step 2
– Work out the position of your
rainbank
®
with regard to distance to
power. the float switch lead is not an
issue here.
Step 4
– align the rainbank
®
for easy
fitting to the plumbing and fit Davey wall
bracket if required.
Step 5
– connect rainbank
®
to your
submersible pump as per instructions on
page 25.
Step 6
– connect the rainbank
®
to the
plumbing as for Installation type 1 on
page 19.
Step 7
– connect all leads as per
Installation type 1 on page 20. there is
no float switch lead as this is fitted to the
submersible pump.
Step 8
– test the unit - page 21.
INSTAllATION TYPE 3
below ground tank with submersible
pump D42a/b & D53a/b
IMPORTANT
• under australian standard 3500
collecting/storing rainwater in a
partially buried tank is considered
a medium level hazard. even though
rainbank
®
has a built-in dual check
back flow valve, you may be required
to fit additional backflow protection
valves to satisfy this requirement –
check with your local council as to
their guidelines on rainwater tank
installation and backflow prevention.
there is no need for a separate float
switch as this comes attached to the
submersible pump and does not plug
into the rainbank
®
unit.
!
puMp InsIDe tank
optIon - close up
TO
TO
ILETS
AND/OR LAUNDR
Y
(do not mix/cross-connect with mains water supply)
MAIN
S
WA
TER SUPPL
Y
3/4" BSP
M
RAINW
ATE
R
SUPPL
Y
from discharge of auto submersibl
e
rainwater pum
p
Power to pump vi
a
3 pin socket - plug th
e
rainwater pump in here.
Incoming power
to RainBank
®
via 3 pin plug
3/4" BSP
M
1" BSP
M
Stop valv
e
200 Micro
n
‘Y’ Straine
r
* Pressure Limiting Valv
e
WHERE MAINS PRESSURE EXCEEDS 900kPa. A PLV*
MUST
BE FITTED TO INLET!
Mains In
To House
W
ARNING: DO NOT
INST
ALL
CHECK
V
AL
VES BETWEEN PUMP
AND RAINBANK
®
.
IMPORTANT: ALL PIPEWORK AND OUTLET FITTINGS FROM RAINBANK
®
MUST BE LA-
BELLED TO AS3500. DO NOT CONNECT WITH CRIMPED FITTINGS.