Series DT Detector position sensors consist of two basic components,
a hermetically sealed reed switch sensor assembly and a magnetic
actuator assembly. A change in state of the contacts in the sensor is
initiated by moving the actuator closer to or further away from the sensor
target area, either into or away from the reed switch magnetic sensing
range. This opens or closes the electrical circuit.

SENSORS
Detector sensors are 316 SS bolts with 5/8˝-18 UNF external threads
and a 1/2˝-14 NPT conduit entrance. The durable SPDT reed switch is
potted inside the sensor enclosure.

ACTUATORS
The actuator is a 316 SS bolt with a magnet embedded in the head. The
available actuators provide levels of sensitivity for either 0.1˝ or 0.5˝
sensing capability.

MECHANICAL INSTALLATIONS
1. The sensor(s) and actuator may be mounted in any position. Choose
orientation that best fits your needs.
2. Install sensors individually, side-by-side, facing the same direction, at
90° or facing each other at a minimum of 3˝ apart.
3. Determine desired operating point. Use actuator supplied with sensor,
keeping all magnetic materials away from the sensor assembly.
4. Locate sensor and actuator mounting assemblies to assure the
actuator will move within the switch sensing area.
5. Adjust setpoints by rotating either the sensor or actuator or both in
their respective threaded bracket assemblies. This will move them closer
together or farther apart for desired operation.

Bulletin F-80-DT

Specifications - Installation and Operating Instructions

Series DT Detector Position Sensor

PROXIMITY CONTROLS DIV., DWYER INSTRUMENTS, INC.

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360 U.S.A.

Phone: 219/879-8000

www.dwyer-inst.com

Fax: 219/872-9057

e-mail: [email protected]

DETECTOR

1.000 HEX

1/29 – 14 NPT

1.250

(3.18 CM)

3.750

(9.525 CM)

5/89 – 18 UNF

1.750

(4.45 CM)

DETECTOR

ACTUATOR

ACTUATOR

TM

ELECTRICAL CONNECTIONS
Use a 18 AWG, 4-conductor, shielded cable or 1/2˝ NPT conduit
connectors. For correct wiring refer to the wiring diagram (Ground:
Green, NC: Red, NO: Black and Common: White). Long runs of cable or
conduit should be supported at the sensor to avoid pulling it out of
position. For installation in hazardous locations, check local electrical
codes. The Detector position sensors are designed to NEMA 4, 4X, 7 ,
9.

Standard Actuator with DT1060

High Strength Actuator with DT1160

(3/8–16 UNC X 3/4˝)

(1/2–13 UNC X 3/4˝)

SPECIFICATIONS
Temperature Limits:
-40 to 163°F (-40 to 73°C).
Switch Type: Tungsten, SPDT, Form C.
Electrical Rating: 3A @ 125 VAC, 3A @ 30 VDC.
Enclosure Rating: Weatherproof; Hermetically Sealed; Explosion-
proof UL & CSA Listed for Class I, Groups A, B, C, & D; Class II,
Groups E, F & G. Divisions 1 & 2.
Intrinsically Safe: Simple Apparatus (w/barrier).
Operating/Response Time: 3.0 m Sec.
Initial Contact Resistance: 0.50 ohms (Max).
Repeatability: 0.005 in. (.01 cm).
Hysteresis: 0.030 in. (.08 cm).
Electrical Connection: Factory sealed leads with 18˝ minimum, 4
conductor, PVC insulated, 18 AWG – Green/Red/Black/White
(Ground/NC/ NO/Common).
Housing: 316 SS.
Potting: Epoxy Resin.
Conduit: 1/2˝-14˝ female NPT.
Weight: 0.32 lb (145 g); 0.45 lb (204 g) with actuator.
Agency Approvals: CSA, UL, cUL.

Model
DT1060
DT1160

Description
Detector and standard actuator
Detector and high strength actuator

Sensing Distance
0.1˝ (2.54 mm)
0.5˝ (12.7 mm)

SINGLE-POLE DOUBLE-THROW

DETECTOR WIRING DIAGRAM

GREEN

(GRD)

WHITE

(C)

BLACK

(NO)

RED

(NC)

©Copyright 2013 Dwyer Instruments, Inc.

Printed in U.S.A. 1/13

FR# 443366-00 Rev. 3