Dwyer PV User Manual

W.e. anderson div., dwyer instruments, inc, Series pv solenoid pilot valve

Advertising
background image

The Series PV three-way normally closed electro-pneumatic
solenoid pilot valve effectively regulates supply pressures for the Series
SAV Angle Seat Valve. The DIN connector is reversible 180 degrees
to keep electrical wiring hassle-free, while the direct mounting banjo
connection simplifies valve installation. Select the proper model
according to the SAV valve actuator diameter and power requirements.

INSTALLATION
1) Examine valve for transport damage.
2) Compare the technical description of valve on valve tag (on top of

the coil) with your application requirements.

3) Keep dirt and debris out of valve and piping.
4) DO NOT use valve or coil as a lever when installing.
5) To fit the solenoid valve onto a normally closed SAV valve, use the

pilot connection marked “NC”; for normally open valves use the
connection marked “NO”.

6) When using water as a pilot media, remove the cap from the

exhaust connection and connect a drain line.

7) Automatic operation is standard. For manual (exhaust) operation,

turn override screw 180° counter-clockwise. Override screw is
identified by “O” and “C” engravings.

8) Make all electrical and plumbing connections in accordance with

federal, state, and local regulations.

INSTRUCTIONS FOR ELECTRICAL PLUG
(see diagram below)
1) Place your 18 gauge SVT or equal wire into #7, 6, 5, and 4,

in that order.

2) Terminate your wire into the cable fixing screws #3 and the

other pole screw termination.

3) The ground or earth termination lies in-between #3 and the

other termination screw.

4) Reassemble the connector. The valve can now be directly

mounted (banjo connection) onto the actuator.

SPECIFICATIONS
Pilot media: Air, water, or inert gases.
Power Requirements: See model chart.
Wetted Materials:

Body: Niploy coated brass;
Seal: FKM.

Maximum Supply Pressure: 150 psig.
Temperature Limits: 14 to 140°F (-10 to 60°C).
Actuator Connection: PV1_: 1/8˝ BSP; PV2_, PV3_: 1/4˝ BSP.
Pilot Media Connection: 1/8˝ NPT.
Coil Consumption:

PV1_, PV2_: AC: 9A (res.), 14A (ind.); DC: 6A.
PV3_: AC: 15A (res.), 30A (ind.); DC: 10A.

Mounting: Banjo connection.
Enclosure Rating: IP65 (with DIN connector).
Standard Features: Manual override, DIN connector.

GROUND

TERMINAL

B

C

DIN CONNECTOR

A

W.E. ANDERSON DIV., DWYER INSTRUMENTS, INC.

P.O. BOX 358 • MICHIGAN CITY, INDIANA 46360 U.S.A.

Phone: 219/879-8000

www.dwyer-inst.com

Fax: 219/872-9057

e-mail: [email protected]

Series PV Solenoid Pilot Valve

Specifications - Installation & Operating Instructions

Bulletin F-89-PV

©Copyright 2014 Dwyer Instruments, Inc.

Printed in U.S.A. 3/14

FR# RV-443112-10 Rev. 3

Model

PV11

PV12
PV13
PV14
PV21
PV22
PV23
PV24
PV31
PV32
PV33
PV34

Voltage

240VAC
120VAC

24VAC

24VDC

240VAC
120VAC

24VAC

24VDC

240VAC
120VAC

24VAC

24VDC

SAV

Actuator

Diameter

1-3/4"

2-1/2"

3-9/16"

A in.

(mm)

1-1/4

(31.8)

1-3/8

(35.0)

1-3/8

(35.0)

B in.

(mm)

3-1/32

(77.0)

3-1/16

(77.8)

3-3/4

(95.3)

C in.

(mm)

1-1/16

(27.0)

1-1/16

(27.0)

1-1/16

(27.0)

Weight

lbs.(kg)

0.6

(0.27)

0.6

(0.27)

0.84

(0.38)

MODEL CHART AND DIMENSIONS

MAINTENANCE
Upon final installation of the Series PV Solenoid Pilot Valve, no routine
maintenance is required. A periodic check of the system calibration is
recommended. The Series PV is not field serviceable and should be
returned if repair is needed (field repair should not be attempted and
may void warranty). Be sure to include a brief description of the
problem plus any relevant application notes. Contact customer service
to receive a return goods authorization number before shipping.

®

1. Gasket
2. Terminal Block

3. Cable Fixing Screws
4. Housing

5. Grommet
6. Washer

7. Gland Nut
8. Fixing Screw

Advertising