UEi Test Instruments KM940 User Manual

Page 24

Advertising
background image

- 24 -

7.

STORING AND RETRIEVING DATA


The KANE940 can store up to 100 combustion tests. Once stored, the data can be viewed on
the display or downloaded to a PC or printer.

7.1 Storing a ‘Live’ Test

While performing a test and viewing the data on the MAIN display access the STORE menu
as follows :-

Press STORE

MENU

to access the STORE MENU

MODE
LOCATION

:

S

TORE

: 3

PRESS ‘STORE’ TO LOG


Mode:

Select from the following :-

STORE - Allows data to be stored in memory.

VIEW / PRINT - Stored data can be viewed or printed.

DELETE - Clears all data in memory.


Location:

Automatically allocates a location in the memory of the instrument for the next
test. On the display shown above the next location will be 3.


To store a test set MODE to STORE and press . The current readings will be stored in
the analysers memory.

Tip :

Make a note of the location number for your particular test as it may be useful
when downloading or printing.

7.2 Viewing and Printing a ‘Stored’ Test

Multiple tests can be printed easily with the KANE940.

Select PRINT under MODE in the STORE menu. This feature is in addition to the
VIEW/PRINT, STORE and DELETE options.

Press STORE

MENU

to access the STORE MENU

MODE
LOCATION

:

P

RINT

: 1 TO 10

PRESS ‘PRINT’

The cursor will move to the first number, use the and to select the location and
start printing.

Press to move the cursor to the second number, select the last location to print.

Advertising