Physical requirements, Environmental requirements, 12 rackmount enclosure dimensions – HP 2000SA G2-Modular-Smart-Array User Manual

Page 63: 13 rackmount enclosure weights, 14 operating environmental specifications

Advertising
background image

HP 2000sa G2 Modular Smart Array User Guide

63

NOTE:

Connections to this device must be made with shielded cables with metallic RFI/EMI connector

hoods in order to maintain compliance with FCC Rules and Regulations.

Physical requirements

The floor space at the installation site must be strong enough to support the combined weight of the rack,

controller enclosures, expansion enclosures, and any additional equipment. The site also requires sufficient

space for installation, operation, and servicing the enclosures, and also requires sufficient ventilation to

allow a free flow of air to all enclosures.

Table 12

and

Table 13

list enclosure dimensions and weights. Weights are based on an enclosure having

12 drive modules, two controller or expansion modules, and two power supplies installed.

.

.

Environmental requirements

Table 12

Rackmount enclosure dimensions

Specifications

Rackmount

Height

3.5 inches (8.9 cm)

Width:

17.55 inches (44.58 cm)

Depth:

Excluding cables

To

back of power supply handle

21.3 inches (54.0 cm)
23.7 inches (60.2 cm)

Table 13

Rackmount enclosure weights

Specifications

Rackmount

2312sa G2 Modular Smart Array

SAS drives

SATA drives

64.5 lb (29.3 kg)
65.5 lb (29.8 kg)

2324sa G2 Modular Smart Array

SAS drives

SATA drives

58.5 lb (26.6 kg)
54.2 lb (24.6 kg)

MSA2000 3.5" 12-drive enclosure

(12 drives)

SAS drives

SATA drives

62 lb (28.2 kg)
63 lb (28.6 kg)

Table 14

Operating environmental specifications

Specification

Range

Altitude

To 9842 feet (3000 meters), derate 35.6ºF (2ºC)

for every 3281 feet (1 km) up to 9842 feet (3000

meters)

Relative humidity

10% to 90% RH, 104ºF (40ºC) non condensing

Temperature

41ºF to 104ºF (5ºC to 40ºC)

Shock

5.0 g, 10 ms, half-sine

Vibration

0.5 g, 1 octave/minute, 5 Hz to 500 Hz to 5

Hz, swept-sine

Advertising