Enhanced snmp configuration – HP Virtual Connect Enterprise Manager Software User Manual

Page 26

Advertising
background image

Virtual Connect 2.3x features that must be disabled in a VC Domain to be part of the VC Domain
Group with Virtual Connect firmware 2.1x

IMPORTANT:

If you plan to add Virtual Connect 2.3x to a VC Domain Group with Virtual Connect firmware

2.0, you must disable the Virtual Connect 2.3x features in this section and the Virtual Connect 2.1x features
in the following section.

Enhanced SNMP configuration is not supported.

Figure 3-2 Enhanced SNMP configuration

Do not configure the VC Domain using the enhanced SNMP configuration. If necessary, disable the
enhanced SNMP configuration by following these steps:

1.

Do not configure more than five SNMP trap destinations.

2.

Verify that all SNMP trap destinations follow these rules:
a.

The Destination Name must be in the following format:

<IP Address of the SNMP Trap Destination>_<Community String>_<0 for

VC-Enet and 1 for VC-FC>

(for example, 192.168.1.1_public_1)

b.

Select the “ipv4” option.

c.

Set the SNMP trap format to “SNMPv1.”

Figure 3-3 Adding or editing a compatible SNMP trap destination

26

Managing VC Domains

Advertising