Component identification 18

System LED and
Color

Internal Health
LED Color

Status

Amber

DIMM in slot X has reached single-bit correctable error

threshold.

DIMM in slot X is in a pre-failure condition.

DIMM in slot X is an unsupported type, but valid
memory exists in another bank.

DIMM failure, all slots
in one bank (amber)

Red

No valid or usable memory is installed in the system.

Overtemperature

(amber)

Amber

The Health Driver has detected a cautionary temperature

level.

Red

The server has detected a hardware critical temperature

level.

Fan module (red)

Red

The minimum fan requirements are not being met in one or
more of the fan modules. One or more fans have failed or

are missing.

Power supply signal
interlock (amber)

Red

The power supply signal cable is not connected to the
system board.

Internal USB connector