Hot-plug fans – HP ProLiant DL385p Gen8 Server User Manual

Page 21

Advertising
background image

Component identification 21

1 - Amber

2 - Green

3 - Green

Interpretation

Off

Off

Off

The cache module is not powered.

Off

Flashing 0.5 Hz Flashing 0.5 Hz The cache microcontroller is executing from within its

boot loader and receiving new flash code from the host

controller.

Off

Flashing 1 Hz

Flashing 1 Hz

The cache module is powering up, and the capacitor

pack is charging.

Off

Off

Flashing 1 Hz

The cache module is idle, and the capacitor pack is

charging.

Off

Off

On

The cache module is idle, and the capacitor pack is

charged.

Off

On

On

The cache module is idle, the capacitor pack is charged,

and the cache contains data that has not yet been
written to the drives.

Off

Flashing 1 Hz

Off

A backup is in progress.

Off

On

Off

The current backup is complete with no errors.

Flashing 1 Hz

Flashing 1 Hz

Off

The current backup failed, and data has been lost.

Flashing 1 Hz

Flashing 1 Hz

On

A power error occurred during the previous or current
boot. Data may be corrupt.

Flashing 1 Hz

On

Off

An overtemperature condition exists.

Flashing 2 Hz

Flashing 2 Hz

Off

The capacitor pack is not attached.

Flashing 2 Hz

Flashing 2 Hz

On

The capacitor has been charging for 10 minutes, but

has not reached sufficient charge to perform a full
backup.

On

On

Off

The current backup is complete, but power fluctuations

occurred during the backup.

On

On

On

The cache module microcontroller has failed.

Hot-plug fans

CAUTION:

To avoid damage to server components, fan blanks must be installed in fan bays 1

and 2 in a single-processor configuration.

The only two valid fan configurations are listed in the following table.

Configuration

Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6

1 processor

Fan blank

Fan blank

Fan

Fan

Fan

Fan

2 processors

Fan

Fan

Fan

Fan

Fan

Fan

Advertising