Fbwc module leds, Hot-plug fans, Fbwc module leds hot-plug fans – HP ProLiant DL385 G7 Server User Manual

Page 20

Advertising
background image

Component identification 20

FBWC module LEDs

The FBWC module has two single-color LEDs (green and amber). The LEDs are duplicated on the reverse
side of the cache module to facilitate status viewing.

Green LED

Amber LED

Interpretation

Off

On

A backup is in progress.

Flashing (1 Hz)

On

A restore is in progress.

Flashing (1 Hz)

Off

The capacitor pack is charging.

On

Off

The capacitor pack has completed charging.

Flashing (2 Hz)
Alternating with
amber LED

Flashing (2 Hz)
Alternating with
green LED

One of the following conditions exists:

The charging process has timed out.

The capacitor pack is not connected.

On

On

The flash code image failed to load.

Off

Off

The flash code is corrupt.

Hot-plug fans

CAUTION:

To avoid damage to server components, fan blanks must be installed in fan bays

5 and 6 in a single-processor configuration.