Appendix B: HP SNMP events 37


Trap types

Rules file

Description

Netcool

severity

cpqHe3PowerConverterRedunda
ncyLost (6045)

6045

This event occurs when the DC-DC
power converters have lost

redundancy for the specified
chassis.

Major (4)

cpqHe3CacheAccelParityError

(6046)

6046

This event occurs when a cache

accelerator parity error indicates a
cache module must be replaced.

Major (4)

cpqHeResilientMemOnlineSpare

Engaged (6047)

6047

This event occurs when the

Advanced Memory Protection
subsystem detects a memory fault
and online spare memory has

been activated.

Major (4)

cpqHe4FltTolPowerSupplyOk

(6048)

6048

This event occurs when the fault

tolerant power supply condition
returns to the OK state for the

specified chassis and bay location.

Clear (0)

cpqHe4FltTolPowerSupplyDegra
ded (6049)

6049

This event occurs when the fault
tolerant power supply condition is

set to Degraded for the specified

chassis and bay location.

Major (4)

cpqHe4FltTolPowerSupplyFailed

(6050)

6050

This event occurs when the fault

tolerant power supply condition is
set to Failed for the specified

chassis and bay location.

Major (4)

cpqHeResilientMemMirroredMe
moryEngaged (6051)

6051

This event occurs when the
Advanced Memory Protection

subsystem detects a memory fault
and Mirrored memory is activated.

Major (4)

cpqHeResilientAdvancedECCMe

moryEngaged (6052)

6052

This event occurs when the

Advanced Memory Protection
subsystem detects a memory fault

and Advanced ECC is activated.

Major (4)

cpqHeResilientMemXorMemoryE

ngaged (6053)

6053

This event occurs when the

Advanced Memory Protection
subsystem detects a memory fault

and XOR engine memory is
activated.

Major (4)

cpqHe3FltTolPowerRedundancyR

estored (6054)

6054

This event occurs when the fault

tolerant power supplies return to a
redundant state for the specified

chassis.

Clear (0)

cpqHe3FltTolFanRedundancyRest

ored (6055)

6055

This event occurs when the fault

tolerant fans return to a redundant
state for the specified chassis.

Clear (0)

cpqHe4CorrMemReplaceMemM
odule (6056)

6056

This event occurs when the
correctable memory errors are

corrected, but the memory module
should be replaced.

Major (4)