Removing a managed system does not change the numbering scheme.

If you want to reuse a node number, remove it from this file and reconfigure the Insight Control
for Linux Management Services with the Options

IC-LinuxConfigure Management Services

menu item.

There are three fields in each non-blank or non-comment line in this file; they are:

number name GUID

Where:

number

Is the node number of the managed system. This number must be nonnegative.

name

Is the name by which HP SIM identifies the managed system, for example, mars.

GUID

Is the globally unique identifier for that managed system. This field is optional but,
if provided, it overrides the name field. This is particularly effective if you want to
ensure that a specific managed system always has the same internal node name, even
if it is renamed.

You can obtain the GUID for a given managed system with the following command:

$ mxnode -ld nodename | grep GUID
GUID: xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx

The following rules apply:

The managed systems can be listed in any order in the file; that is, order does not matter.
The configuration task reorders the file.

You are allowed to have gaps in the numeric sequence.

If a number is repeated with different names or GUIDs, only the first instance in the file is
used. Subsequent entries with that number are lost.

If two entries have the same GUID, only the first entry is used.

Comment lines begin with a nonnumeric character, usually #, in the first field.

Blank lines and comments are ignored and, thus, are not preserved.

The following is an example of an edited nodenumbers file:

# Nodenumbers file

1 earth xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
3 mercury
4 mars
5 pluto nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn

The configuration task assigns these managed systems internal node names as follows:

earth

icelx1

mercury

icelx3

mars

icelx4

pluto

icelx5

Where icelx is the collection name.

1.13.2 Viewing managed system names

After the Configure Management Services task is run, you can display a list of all managed
systems with their associated names; use the shownode info command as described in