Some of the following items are adjusted by typing the desired values using the numeric
keypad and press the <Enter> key. You can also use the <+> and <-> keys to adjust the
value. To restore the default setting, type [auto] using the keyboard and press the <Enter>
key.

DRAM Current Capability [Auto]

A higher value brings a wider total power range, and extends the overclocking range
simultaneously.

Configuration options: [100%] [110%] [120%] [130%]

DRAM Voltage Frequency [Auto]

Allows you to adjust the DRAM switching frequency. Assign a fixed high DRAM frequency to

increase the O.C. range, or a low DRAM frequency for a better system stability.

Configuration options: [Auto] [Manual]

DRAM Fixed Frequency Mode [300]

This item only appears when you set the DRAM Frequency Mode item to [Manual], and

allows you to set a fixed DRAM frequency. Use the <+> and <-> keys to adjust the value. The

values range from 300k Hz to 500k Hz with a 10k Hz interval.

DRAM Power Phase Control [Auto]

[Auto]

Allows you to set the Auto mode.

[Optimized]

Allows you to set the ASUS optimized phase tuning profile.

[Extreme]

Allows you to set the full phase mode.

DRAM Power Thermal Control [110]

A higher temperature brings a wider DRAM power thermal range, and extends the
overclocking tolerance to enlarge the O.C. potential. Use the <+> and <-> keys to adjust the
value. The values range from 110 to 131.

DO NOT remove the thermal module. The thermal conditions must be monitored.

CPU Voltage [Offset Mode]

[Manual Mode] Allows you to set a fixed CPU voltage.

[Offset Mode]

Allows you to set the Offset voltage.

Offset Mode Sign [+]

This item appears only when you set the CPU Voltage item to [Offset Mode].

[+]

To offset the voltage by a positive value.

[–]

To offset the voltage by a negative value.

CPU Offset Voltage [Auto]

This item appears only when you set the CPU Voltage item to [Offset Mode] and
allows you to set the Offset voltage. The values range from 0.005V to 0.635V with a
0.005V interval.