Chapter 3 ________________________________________________________________ Installation

VAISALA ________________________________________________________________________ 29

Wiring

Connect the wiring to the screw terminals on the mounting base. The

supply voltage and terminal assignments are model-specific. Max wire

size 2 mm

2

(AWG14).

After completing the wiring, connect the transmitter body over the

mounting base. Note that mounting bases are model-specific.

WARNING

Connect only de-energized wires.

NOTE

When wiring the transmitter, make sure the electrical conduit or cable is

not supplying air from outside the room into the transmitter. Seal the

cable opening if necessary.

Wiring HMW92

You must connect the RH channel of the HMW92, even if you only want

to measure temperature. Connecting the T channel is optional.

1111-067

Figure 12

Wiring HMW92

If you want to use a single power supply for the HMW92, you must

connect the positive terminals (+T and +RH) together.

1211-007

Figure 13

Three-Wire Wiring for HMW92

-T

-RH

+T

+RH

Power supply

10 ... 28 VDC

R

L

= 0 ... 600 Ω

Power supply

10 ... 28 VDC

R

L

= 0 ... 600 Ω

mA

mA

-T

-RH

+T

+RH

mA

mA

Power supply

10 ... 28 VDC

R

L

= 0 ... 600 Ω

Advertising