Vt-11 – Videoswitch VT User Manual

Page 18

Advertising
background image

VT Series 2

User Manual

Page 18

Videoswitch

VT601c.doc

8.4 Interval Switching Mode

This switch should be set off if the cameras are synchronised (gen-locked). It should be set on if the
cameras are not synchronised to avoid picture bounce during switching.

S1-7

Interval Switching Mode

OFF

Immediate switch-over at vertical sync

ON

Blank fields inserted between vertical sync

pulses during switch-over

8.5 SET Lockout

All SET function for both the switcher set-up and receiver set-up can be locked out. Once the required
settings have been made, it is advisable to set the lockout switch to on to avoid accidental alteration of any
of the settings.

VT-11:

S3-1

SET Functions Lockout

OFF

SET functions not locked out

ON

SET functions locked out


VT-14A, VT-18A and VT-28A:

S1-8

SET Functions Lockout

OFF

SET functions not locked out

ON

SET functions locked out

8.6 Camera Termination

The camera inputs are provided with switchable termination:

Switch

Camera

Input

OFF

ON

S2-1

1

Not Terminated

75

Termination

S2-2

2

Not Terminated

75

Termination

S2-3

3

Not Terminated

75

Termination

S2-4

4

Not Terminated

75

Termination

S2-5

5

Not Terminated

75

Termination

S2-6

6

Not Terminated

75

Termination

S2-7

7

Not Terminated

75

Termination

S2-8

8

Not Terminated

75

Termination

Advertising