4 connecting to more than one digital recorder – Videoswitch VK-1 User Manual

Page 8

Advertising
background image

VK-1 Remote Keyboard

User Manual

23/09/2004 11:09

Videoswitch Page

7 Vk602b.doc

1.4 Connecting to more than one Digital Recorder

Digital Recorders can be daisy-chained as illustrated in the diagram below. This configuration allows one or
more keyboards to control multiple Digital Recorders. It also ensures that the clocks of the Digital Recorders
are kept exactly in step (within a second). If the time and date needs adjusting, adjust clock of the “Master”.
The “Slave” will be updated automatically (every minute).

DIGITAL RECORDER (CLOCK MASTER)

DIGITAL RECORDER (CLOCK SLAVE)

Connect to

“IN+” and “IN-”

Connect to

“IN+” and “IN-”

of all other slave VDMs

TWISTED-PAIR

CABLE

T25A

TERMINAL PCB

RS485 TERMINATION = ON

CAT5 CABLE

to

KEYBOARD(S)

Connect to

“OP+” and “OP-”

The last slave VDM should have its RS485 termination ON,

other slaves should have RS485 termination OFF

Note:

RS485 termination may be switched ON either using the switch on the T25A PCB or using the miniature
slide switch on the rear of the VDM. Do not turn both termination switches ON.

Advertising