The operating point of the switch is adjustable by turning the set screw located
in the end of the body near the spring. The minimum operating point is .187"
and the maximum recommended height is .250". Each 1/4 turn of the adjusting
screw changes the operating point about .012". The operating point should be
adjusted to .010" to .015" before the end of the ejector plate stroke.

Adjusting

the operating point greater than .020" before the end of the ejector plate
stroke can result in premature spring failure which can leave the switch
inoperable.
Wiring should be in accordance with prevailing electrical wiring
standards. The Thinswitch can be wired direct to injection molding machine con-
trols or to an approved locking male plug. The matching electrical receptacle
approved outlet box with cover plate can be mounted to the molding machine
for convenience.

LIMITED WARRANTY

Seller warrants that this product supplied will conform to the description herein stated
and that the product will be of standard quality. This is the sole warranty made by Seller
with respect to this product. Seller expressly disclaims any other express or implied war-
ranties, including, but not limited to, the implied warranty of merchantability and the
implied warranty of fitness for a particular purpose.

Seller shall not be liable for any cost or damages, whether direct, incidental or conse-
quential, including, but not limited to, any injury, loss or damage resulting from the use of
this product, regardless of whether any claim for such cost or damages is based on
warranty, contract, negligence, tort or strict liability. The sole liability of Seller is limited to
repairing or replacing this product.

This warranty shall not apply to any products that have been repaired or altered by any-
one other than Seller. The warranty shall not apply to any products subject to misuse
due to common negligence or accident, nor to any products manufactured by Seller
which are not installed or operated in accordance with the printed instructions of Seller
or which have been operated beyond the rated capacity of the goods