11 maintaining and cleaning, 1 maintaining, 1 firmware updating – Videotec ULISSE COMPACT HD User Manual

Page 29: 2 fuses replacement, 2 cleaning, 1 window and plastic cover cleaning, 1 firmware updating 11.1.2 fuses replacement

Advertising
background image

Instruc

tions manual - English - EN

29

MNVCUCHD_1405_EN

11 Maintaining and
cleaning

11.1 Maintaining

Maintenance must be carried out by

personnel trained to operate on electrical

circuits.

11.1.1 Firmware updating

The H.264 encoder firmware can be

upgraded directly from the web interface.

If necessary it is possible to update the pan & tilt

firmware.
For further information please contact the VIDEOTEC

service center.

11.1.2 Fuses replacement

For continued protection against risk of fire,

replace only with same type and rating of

fuse. Fuses must be replaced only by service

personnel.

There are two preset fuses on the connection board.

FUS1

FUS2

Fig. 53

Their sizes are related to the power supply voltage.

FUSES REPLACEMENT

Voltage

Fuse F1

Fuse F2

24Vac, 50/60Hz

T 4A L 250V 5x20

T 6.3A H 250V 5x20

120Vac, 50/60Hz

T 4A L 250V 5x20

T 4A H 250V 5x20

230Vac, 50/60Hz

T 4A L 250V 5x20

T 2A H 250V 5x20

Tab. 8

11.2 Cleaning

Die Schwenk-Neige-Köpfe bedürfen keiner

aufwendigen Wartung. Für die Reinigung des

Gerätes Neutralreiniger und nicht schleifende Tücher

benutzen. Es sei daran erinnert, dass die Einrichtung

wasserundurchlässig ist.

11.2.1 Window and plastic cover

cleaning

Avoid ethyl alcohol, solvents, hydrogenated

hydrocarbide, strong acid and alkali. Such

products may irreparably damage the

surface.

Surface dirt should be rinsed away with water and

then the window cleaned with a neutral soap diluted

with water, or specific products for spectacle lens

cleaning. These should be applied with a soft cloth.

Advertising