11 maintaining and cleaning, 1 maintaining, 1 firmware updating – Videotec ULISSE COMPACT HD User Manual
Page 29: 2 fuses replacement, 2 cleaning, 1 window and plastic cover cleaning, 1 firmware updating 11.1.2 fuses replacement
Instruc
tions manual - English - EN
29
MNVCUCHD_1405_EN
11 Maintaining and
cleaning
11.1 Maintaining
Maintenance must be carried out by
personnel trained to operate on electrical
circuits.
11.1.1 Firmware updating
The H.264 encoder firmware can be
upgraded directly from the web interface.
If necessary it is possible to update the pan & tilt
firmware.
For further information please contact the VIDEOTEC
service center.
11.1.2 Fuses replacement
For continued protection against risk of fire,
replace only with same type and rating of
fuse. Fuses must be replaced only by service
personnel.
There are two preset fuses on the connection board.
FUS1
FUS2
Fig. 53
Their sizes are related to the power supply voltage.
FUSES REPLACEMENT
Voltage
Fuse F1
Fuse F2
24Vac, 50/60Hz
T 4A L 250V 5x20
T 6.3A H 250V 5x20
120Vac, 50/60Hz
T 4A L 250V 5x20
T 4A H 250V 5x20
230Vac, 50/60Hz
T 4A L 250V 5x20
T 2A H 250V 5x20
Tab. 8
11.2 Cleaning
Die Schwenk-Neige-Köpfe bedürfen keiner
aufwendigen Wartung. Für die Reinigung des
Gerätes Neutralreiniger und nicht schleifende Tücher
benutzen. Es sei daran erinnert, dass die Einrichtung
wasserundurchlässig ist.
11.2.1 Window and plastic cover
cleaning
Avoid ethyl alcohol, solvents, hydrogenated
hydrocarbide, strong acid and alkali. Such
products may irreparably damage the
surface.
Surface dirt should be rinsed away with water and
then the window cleaned with a neutral soap diluted
with water, or specific products for spectacle lens
cleaning. These should be applied with a soft cloth.