This product can mount to either a 4" square electrical box with

round plaster ring or an octagon electrical box.

This product is suitable for damp locations.

Install the Fixture

1

Place the ballast inside the electrical box.

Mount the crossbar assembly to the electrical box holes with

the two #8-32 screws provided.

Connect the crossbar to a suitable ground in accordance with

local electrical codes.

CROSSBAR
ASSEMBLY

#8-32 SCREW

BALLAST

ELECTRICAL BOX

Connect the white ballast wire to the neutral power line wire

with a wire nut.

Connect the black ballast wire to the hot power line wire with

a wire nut.

BALLAST

1A

1B

CAUTION - RISK OF FIRE

This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.

Use minimum 90°c supply conductors.