Installation Instructions for

Tear Drop Wall

1.8

HW4601_SC2G60

980TEARDW

G

P

I

:

ENERAL

RODUCT NFORMATION

This product can mount to either a 4" square electrical box with

round plaster ring or an octagon electrical box.

This product is suitable for damp locations.

This product can be dimmed with a standard incandescent dimmer.

Install the Fixture

Mount the crossbar assembly to the electrical box holes with

the two #8-32 screws provided.

CROSSBAR
ASSEMBLY

ELECTRICAL BOX HOLE

#8-32 SCREW

Feed the fixture wires through the mounting plate side hole.

Connect the crossbar to a suitable ground in accordance with

local electrical codes.

Connect the fixture white wire to the neutral power line wire

with a wire nut.

Connect the fixture black wire to the hot power line wire with

a wire nut.

FIXTURE
WIRES

GROUND WIRE SCREW

1

MOUNTING PLATE

CAUTION - RISK OF FIRE

This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.

Use minimum 90°c supply conductors.