Installation Instructions for

Dover Bath (Compact Fluorescent)

1.2

PW496OP_24L_HE

980DOVERBWCF

G

P

I

:

ENERAL

RODUCT NFORMATION

This product can mount to either a 4" square electrical box with

round plaster ring or an octagon electrical box.

This product is suitable for damp locations.

This product can be mounted horizontally or vertically.

1

Hold the backplate up to the mounting plate. Line up the slots

in the backplate with the inner threaded holes in the mounting

plate.

Adjust the mounting plate as necessary so the backplate is

level when the threaded holes line up with the slots.

Fully tighten the short #8-32 screws to secure the mounting

plate in the desired position.

BACKPLATE

SLOT

SLOT

INNER THREADED HOLE

INNER THREADED HOLE

Install the Mounting Plate

If mounting vertically: Make sure the green ground screw

head faces out of the electrical box.

Make sure the green ground

If mounting horizontally:

screw head faces into the electrical box.

Line up two long inner mounting plate slots with the two

electrical box holes and screw in the short #8-32 screws.

SHORT
SCREW

INNER
THREADED
HOLE

NOTE : These steps assume the threaded electrical box

holes are lined up horizontally. If the holes are lined up
vertically, follow the instructions opposite the desired
mounting direction.

VERTICAL

HORIZONTAL

SHORT
SCREW

LONG
INNER
SLOT

GROUND
SCREW

LONG
INNER
SLOT

GROUND
SCREW
(INSIDE)

Wall

1A

1B

1

2

3

4

5

1

2

1

2

3

CAUTION - RISK OF FIRE

This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.

Use minimum 90°c supply conductors.