Installation Instructions for

60 Watt Electronic Direct Power Feed
Canopy Transformer

980MRLSFELEDDCT-LED

1

1.2

TRANSDIRSFE60_-LED

Install the Power Feed Canopy

#8-32 SCREW

NOTE:

Use the provided universal round crossbar when the

canopy holes do not line up with the electrical box holes.

POWER LINE WIRES

Disconnect power to the electrical box.

Connect the white transformer wire to the neutral power line

wire with a wire nut.

Connect the black transformer wire to the hot power line

wire with a wire nut.

Connect a suitable ground in accordance with local electrical

codes.

Connect the canopy wires to the transformer output wires

with wire nuts.

Place the transformer, wires, and wire nut connections inside

the electrical box.

Mount power feed canopy to the electrical box with the two

#8-32 screws.

TRANSFORMER

G

P

I

:

ENERAL

RODUCT NFORMATION

This product is ETL listed only when all the products used are

supplied by LBL Lighting, is suitable only for indoor dry locations

and approved for use at any height above the finished floor.

This product may be dimmed only with a low voltage electronic

dimmer. Using a dimmer not designed for low voltage electronic

applications may cause undesirable noise and potentially shorten

the life of the transformer.

Minimum volume of the electrical box must be 6 cubic inches (98

cubic centimeters).

This product is intended for use with LBL low voltage lighting

systems only.

Read all instructions thoroughly before beginning installation.

Important Safety Information

To reduce the risk of fire and burns, do not install this lighting
system where the uninsulated open bus bar conductors can be
shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a
fire, make sure all the connections are tight.

Do not install fixture assemblies closer than 6 inches to curtains or
similarly combustible materials.

Turn the electrical power off before modifying the lighting system in
any way.

The fixtures used with the system must be identified to be used
with the corresponding system.

Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).

Load the circuit of the surface mount transformer to no more than
the maximum rated capacity as specified.

1A

1A