LBL Lighting LED Illum MO Flush Elec Xfmr 60w 277v/12v LED User Manual

Important safety information, Adjust the fixture height

Advertising
background image

Installation Instructions for

60 Watt Electronic Flexible Power Feed
Canopy Transformer

980MRLSFELEDFCT-LED

1

1.2

TRANS-SFE60_-LED

G

P

I

:

ENERAL

RODUCT NFORMATION

This product is ETL listed only when all the products used are

supplied by LBL Lighting, is suitable only for indoor dry locations

and approved for use at any height above the finished floor.

This product may be dimmed only with a low voltage electronic

dimmer. Using a dimmer not designed for low voltage electronic

applications may cause undesirable noise and potentially shorten

the life of the transformer.

Minimum volume of the electrical box must be 6 cubic inches (98

cubic centimeters).

This product is intended for use with LBL low voltage lighting

systems only.

Read all instructions thoroughly before beginning installation.

1

The overall fixture height (H) is measured from top of the

canopy to the bottom of the power feed. Leave an additional

4” of the coaxial cable for connecting to power.

Once the height is determined, cut the excess coaxial cable.

(H)

POWER FEED
HOUSING

NOTE:

It is recommended to adjust the power feed

height before installing the canopy.

CANOPY

Adjust the Fixture Height

Important Safety Information

To reduce the risk of fire and burns, do not install this lighting
system where the uninsulated open bus bar conductors can be
shorted or contact any conductive materials.

To reduce the risk of the system overheating and possibly causing a
fire, make sure all the connections are tight.

Do not install fixture assemblies closer than 6 inches to curtains or
similarly combustible materials.

Turn the electrical power off before modifying the lighting system in
any way.

The fixtures used with the system must be identified to be used
with the corresponding system.

Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).

Load the circuit of the surface mount transformer to no more than
the maximum rated capacity as specified.