6. LoggerNet/PC400 Software Setup

The Loggernet “Device Map” is configured from the “Setup” button on the
LoggerNet Toolbar.

Setup has two options, “EZ (simplified)” and “Standard”. Click
on the “View” menu item at the top of the Setup Screen, and
select “Standard” view.

NOTE

From the Loggernet Toolbar, click Main | Setup, and configure the Device Map
as described below.

1. Select Add Root | IPPort.

2. Add a datalogger to the IPPort (PakBus dataloggers; e.g., the CR1000,

require a PakBusPort).

3. On the IPPort page, add the IP address or Domain Name and the Port

number (the RavenXTG template file configures the port to be 3001). Add
four seconds of extra response time.

Example settings for a “Static IP” address:


Preceding zeros are not entered in the Internet IP Address (e.g.,
070.218.074.247 is entered as 70.218.74.247). Follow the IP address with
“:3001”, which is the port number (set by the template file). For modems
configured as “PPP” the port number is “:6785”.

17