Specifications:

On-board memory:

Non-volatile flash for setup parameters. 16 kbytes for
data

Transmission Data
Rates:


100, 300 and 1200 bps

Power requirements:

10.8 to 16 VDC, 5 mA quiescent, 90 mA during GPS
fix and 2.6 Amps during transmission

25316 Transmit
Antenna:


11 dBi Gain, Right Hand Circular polarization, Type
N female connector, wind load of ~100 knots

Transmit power:

5.6 watts for 100 and 300 bps, 11.2 watts for 1200 bps

Frequency Range:

401.701 MHz to 402.09850 MHz

Frequency Stability:

Initial Accuracy: ±20 Hz disciplined to GPS; Short
term drift: ±0.04 Hz/sec, Ageing: ±-0.1 ppm/Year,
Vcc + Temperature: ±-0.1 PPM

Channel Bandwidth:

100/300 bps 1.5 kHz; 1200 bps 3 kHz

Time Keeping:

Initial setting accuracy: ± 100 microseconds
synchronized to GPS; Drift ± 10 milliseconds/day over
operating temperature range; GPS scheduled updates
are 1 at power up and once per day there after. Once
every 28 days required for continual operation

GPS antenna:

3.3 volt active; SMA female connector

RS-232 serial port:

Signal Levels: RS-232C; Connector: DB9F; Command
protocols: ASCII, Binary, Field diagnostics,
Dataloggers with RS-232 port

CS I/O port:

Signal Levels: TTL, Connector DB9M; Command
Protocol: Campbell Scientific Synchronous Device
Communication, Binary Command, Campbell
Scientific Dataloggers.

SDI-12 Port:

Multiplexed with CS I/O port. Protocol SDI-12
Recorder version 1.3

Environmental:

Operating: -40

° to 60°C; Storage -50º to 70ºC; 0 to

99% RH, non-condensing

Dimensions (with
mounts):


6.4” H x 11” L x 2.1” W (16.2 x 27.9 x 5.3 cm)

Weight:

2.1 lbs (0.95 kg)