Alto-Shaam 12.18ESG User Manual

Page 19

Advertising
background image

G A S C O M B I T H E R M

I N S T A L L A T I O N M A N U A L

#MN-28898

PG

. 17

®

C O M B I T HE R M

G A S S U P P LY & I N S TA L L AT I O N R E Q U I R E M E N T S

Remove any tape or

compound residue

on all external

thread connections

before proceeding.

Use an approved gas

pipe sealant at all

external threaded

connections, Gas

piping used on gas

connections must avoid sharp bends that may restrict

the flow of gas to the appliance. If the connected

pressure exceeds 14.0" W.C. (3.5 kPa), a step-down

regulator is required to be supplied by the

owner/operator.

Close the individual manual shut-off valve to

isolate the appliance from the gas supply piping

system during any pressure testing at test pressures

equal to or less than

1/2

psig. (3,4 kPa). The

appliance and individual shut-off valve m u st be

d isconnected from the gas supply piping system

during any pressure testing at pressures in excess of

1/2

"

psig. (3,4 kPa).

In the U.S.A., installation must conform to local
codes or, in the absence of local codes, with the
current edition of the National Fuel Gas Code,
NFPA-54 and ANSI Z83.11a CSA 1.8a 2004 (or
latest edition). In Canada, installation must be in
accordance with local codes, CAN/CGA-B149.1,
Installation for Natural Gas Burning Appliances
and Equipment
(latest edition) or CAN/CGA-
B149.2 Installation for Propane Burning Appliances
and Equipment
(latest edition).

The inlet supply line must be properly sized to

accommodate all individual appliances

simultaneously used on the same line but must

never be smaller than

3/4

"

NPT.

INCORRECT

CORRECT

A

B

C

D

E

F

G

H

GAS INTAKE

A-G Installation elbow

B Wall Valve

C-D Three-piece union fitting

(minimum 1 per installation)

E-F End connector for the flexible tube

H Marking line

C O N N E C T I O N

D A N G E R

Installation, air adjustment and/or
service work must be in accordance
with all local codes and must be
performed by a certified service
technician qualified to work on
gas appliances.

D A N G E R

DO NOT store or use gasoline or other

flammable vapors or liquids in the

vicinity of this or any other appliance.

D A N G E R

DO NOT store or use gasoline or other

flammable vapors or liquids in the

vicinity of this or any other appliance.

Advertising
This manual is related to the following products: