Cabling requirements, General specifications, Optional accessories – Vaddio DomeVIEW Outdoor Pendant Mount User Manual

Page 10

Advertising
background image

Vaddio DomeVIEW Outdoor, Environment Pendant Mount Dome Installation and User Guide - Document 341-445 Rev C

Page 10 of 14

CABLING REQUIREMENTS

For the DomeVIEW 70 Outdoor Pendant Dome and DomeVIEW 50iR Outdoor Pendant Dome that use the
EZCamera Cabling system, the cabling requirements are as follows:
One (1) - Cat. 5 Cable for Power/Video
One (1) - Cat. 5 Cable for RS-232 control input
One (1) - Cat 5 Cable for RS-232 control output for daisy chaining
One (1) - Pair unshielded cable (16AWG or 18AWG) for 24 VAC power supply (100’ / 30.48m Max)

(See system drawings on pages 13)


For the Outdoor Pendant Mount Dome Enclosures that do not use the EZCamera Cabling system, the native
connections on the cameras and original power supply must be used. Custom cables for camera power (12
VDC), heater/blower power (24 VAC), video (S-video or composite video) and control signaling must be
fabricated.

Note: The RS-232 requires at least 5 wires – preferably paired for TXD and RXD as well as DTR/DSR for Sony control daisy
chain and CTS/RTS for Canon control daisy chain. The native control connections of the Sony EVI-D70 uses the 8-pin mini-din
female connector for RS-232 in and RS-232 out, and the Canon uses a proprietary 20-pin connector and also has an adapter
available to convert the 20-pins into 8-pin mini-din although it is pin differently than the Sony 8-pin mini-din. Please see power
supply cable extension disclaimer above.


GENERAL SPECIFICATIONS

Mechanical

Enclosure:

Dual Shell Design; UV Resistant ABS Plastic Outer shell

Dome:

.118” Cell-cast Acrylic

Hardware:

Heavy-gauge steel and Aluminum construction

Weight:

5.26 lbs with heater/blower - camera not included

Electrical

Input Voltage:

24 VAC +/- 10%

Power Requirements

1.8 amps (1 heater, 1 blower) - camera not included

Power Supply:

Power Supply Included, Primary 120VA 60Hz,
Secondary 24VAC, 50VA

Blower:

Two (2) 24.8 CFM @ .006 watts,
Continuous operation at .16 amps

Heater:

One

(1)

40-watt

heater

Operating Range:

With Heater Blower Kit -20°F to 120°F (33°F to 100°F without)

Certifications

Designed to meet NEMA-4 guidelines and
Independently certified to IP66 requirements with proper installation


Optional Accessories:

998-9300-000 Curved Wall Mount
998-9300-001 Curved Wall Mount and Pole Mount Kit
998-9300-002 Ceiling Pendant Mount
451-2000-024 PowerRite 24 VDC power supply

Note: see page 8 for cabling distance using standard and optional power supplies