Problem

It might be caused by

Course of Action

No Water in the wells.

Check to make sure there is power supplied to

the Auto-fill unit.

Verify the switch is ON. Verify the water supply valve is open.

Refer to the installation section and be sure all steps were followed

properly.

Wells are not getting hot enough.

There may be too much water in the wells.

Change the water level to a maximum depth of 3/8”.

No Water in the wells.

The reservoir assembly may be set too low.

Loosen the fasteners and raise the assembly.

The water continues to run and the

water flows out the over flow tube.

There may be a clog in the drain assembly

preventing water from reaching the float or the

drain overflow may be clogged causing an air

lock in the Auto-Fill reservoir.

Make sure drain line is open and water is able to reach the

reservoir. Also, make sure the auto fill system is plugged in and

grounded.

The wells continue to fill beyond

the desired water level.

The float switch may be installed incorrectly.

Disconnect power and remove the control box cover on the outside

of the revisor tank. Check to see that the arrow molded into the

white plastic nut portion of the float switch is pointing DOWN.

S

ervice

and

r

epair

There are no user serviceable parts within this appliance. To avoid serious injury or damage, never attempt to repair the equipment or replace a damaged power

cord yourself. Do not send equipment directly to the Vollrath Company. Please contact the qualified professional repair service listed below.

VOLLRATH Technical Service • 1-800-628-0832

o

peration

WARNING

Electrical Shock Hazard.

Keep water and other liquids from entering the

inside of the equipment.

Liquid could contact the

electrical components and cause a short circuit

or an electrical shock. Do not spray water or

cleaning products. Do not use equipment if power

cord is damaged or has been modified.

1. Check the drain valve of the Hot Food Unit. Make sure it is in the closed

position to prevent water from draining out. Generally, the valve is in the

off position when the handle of the valve forms a “T” with the body of the

valve.

2. Turn Auto-Fill control on. Operate the Vollrath Hot Food Table in

accordance with the Operating and Safety Instructions that were

provided with the Hot Food Table.

3. At the end of the serving period, turn the Auto-fill control off before

opening the drain valve for the Hot Food Unit. If the unit is drained with

the Auto-fill on, the unit will continue to fill and will not completely drain.

4. Follow the shut down and cleaning procedures that were sent with the

Hot Food Table. No special cleaning is required for the Auto-fill system.