I

40

Maximum Input (Btuh)

40,000

Ventilation Air to Support Combustion
Zone Control

PROPANE GAS OR

Full Output Pressure

NATURAL GAS

Zone Control,

PROPANE GAS OR

Low Output Pressure

NATURAL GAS
“A”

31-1/2 in.

“B”

20-1/4 in.

“C”

10-5/8 in.

Net Weight

13 lbs.

PROPANE GAS

1.85 lbs./hr.

NATURAL GAS

CHICKENS

2900 - 4400

TURKEYS

920 - 1100

SWINE

345

CHICKENS

6.5 - 7.5 ft.

TURKEYS

5.5 - 6.5 ft.

SWINE

5 - 6 ft.

TOP OF HOOD TO CEILING

3 ft.

POINT OF COMBUSTION

CONE TO FLOOR
SIDES

3 ft.

44

Radiant Heater Specifications

SSPPEECCIIFFIICCAATTIIOONNSS

M

Mooddeell

FIG. 1

Heater Dimensions

(See Fig. 1)

Fuel Consumption Per Hour

Animal Coverage Per Heater (1)

Minimum Safe Clearances to

Combustible Materials

Recommended Height Installation

For Livestock From Point of

Combustion Cone to Floor

4.5 ft.

40 CFH

10 - 12 in. W.C.

468 CFM

5 PSIG

(1) There are other factors that will affect the quantity of animals

each heater can cover. These include building ventilation and control systems, building insulation, building size and population

density, etc. Consult your L.B. White dealer or call L.B. White for specific recommendations for your application.

(2) This is a typical sensor height range for poultry installations. The size and type of livestock being grown, heater spacing and height,

etc. will dictate sensor height. Care should always be taken to ensure that the sensor is sufficiently high as to not be damaged by

the animal during operation.

"B"

"A"

"C"

Animal Occupied Zone Temperature

Control Sensor Location (2)

VERTICAL FROM FLOOR

6-12 in.

HORIZONTAL FROM BROODER

8-12 ft.

VERTICAL FROM FLOOR

Above Animal Height

HORIZONTAL FROM BROODER

4-8 ft.

POULTRY

SWINE