American Lighting EP3S Series User Manual

3” e-pro led recessed kit, Installation instructions for ep3 and ep3s series

Advertising
background image

WARNING: These products may represent a possible shock or fire hazard if improperly installed or attached in any way.
Products should be installed in accordance with these instructions, and with current electrical codes and/or the current National
Electric Code (NEC).

WARNING: To avoid electric shock or injury to persons, disconnect power prior to installation.

Caution: Injury to persons and damage to the fixture and/or mounting surface may result if the fixture is not
properly installed. To reduce the likelihood of such injury or damage, read and follow all instructions.

Use only a mild soap and water with soft cloth to clean the fixture. Harsh chemicals will damage the finish. Do not wipe the
fixture with a rough cloth that may scratch the finish or the lens.

WARNING: Risk of fire or electric shock. Install the LED Swivel Recessed Fixture only with the 3” housing included.

WARNING: Risk of fire or electric shock. The electrical rating of this product is 120V AC. The installer must determine whether
power supply is 120V AC before installation. The driver in the housing’s junction box must not be removed.

Each 3” E-Pro LED Swivel Recessed Light Kit includes 3-3/8” (86mm) diameter cut-out template; LED light engine (EP3S has
swivel feature, EP3 is standard downlight), integrated lens, trim, heat sink, attached torsion clips to hold recessed downlight in
place and power lead wire with “A” type connector; insulating foam ring; 3” remodel style housing with power lead wire, power
junction box, drywall clips and mating “B” type connector; and these safety/ installation instructions.

INSTALLING RECESSED HOUSING:

To avoid electric shock or injury to persons, disconnect power prior to installation.
1. Determine desired location for light. NOTE: 120V AC supply power is needed in the
ceiling plenum at this location.
2. Using the cut-out template, mark the cutting line for installing the remodel housing.
3. Cut this hole from the drywall or surface material using an appropriate saw or cutting
tool and remove cut-out material. NOTE: The size of the cut-out hole is very important!
Do not exceed 3-3/8“ (86mm) in diameter! Proper installation of housing and light
engine depend upon correct sizing of cut-out.
4. Locate supply power in ceiling plenum. Pull supply wires through cut-out and strip
back conductors 3/8”. See Figure 1.
5. Push upward on the junction box closure clip to release the junction box cover.
See Figure 2.
6. Punch out the knockout that is most suited for the installation. Use UL Listed
cable clamp connector (not included) to provide strain relief for supply wires.
7. Route minimum 18AWG solid copper wires through knockout via cable connector.
Attach line voltage AC supply wires to driver lead wires inside of junction box: Black to
Black, White to White, Green or bare wire to Yellow/Green (Ground). Secure each
connection using the quick connectors provided on the
driver lead wires. See Figure 3.
8. Replace junction box cover by lining up tabs and
pressing firmly until closure clip snaps in place.
NOTE:

Be sure that the wires are not pinched or

damaged by any part of the junction box or its cover.

3” E-Pro LED Recessed Kit

Installation Instructions for EP3 and EP3S Series

Figure 3 - inside junction box

Figure 1

Figure 2

Punch out knockout,

attach cable clamp

and bring supply wires

into the junction box

through the cable

clamp/knockout.

Pull supply wires

through cut-out

and strip back 3/8”.

Push up

on clip

to open.

www.americanlighting.com

RV1251

Page 1 of 2

CONTINUED ON REVERSE.

Advertising
This manual is related to the following products:

EP3