SPECIFICATIONS:
Display: 6-Digit LCD showing hours,

minutes, and seconds.
Accuracy: 6/1000 of a second.
Timing Capacity: 1 second to 23 hours, 59

minutes, 59 seconds.
Alarm: Audible and visual.
Memory: Automatic recall of last

programmed time.
Functions: Countdown timing and countup

(stopwatch) timing.
Attachments: Clip, magnetic back, and stand.
Clock: Time-of-day with AM/PM indicators.

COUNT DOWN ALARM TIMING

1. Switch the TIMER/CLOCK slide switch to

TIMER. The display will show TIMER on

it. If the timer is running press STOP and

then press RESET. The display should

read 0:00 00.

2. Press the HR (hour) button to advance

the hour digits. Each press is confirmed

with a sound. Press and hold down the

HR button to rapidly advance hours.

Press the MIN (minute) button to advance

the minutes digits. Each press is confirmed

with a sound. Press and hold down the MIN

button to rapidly advance minutes.

Press the SEC (second) button to advance

the seconds digits. Each press is confirmed

with a sound. Press and hold down the

SEC button to rapidly advance seconds.

3. When the desired amount of time appears

on the display, press the START button to

begin timing down.

4. When the timer reaches zero an electronic

tone will sound and the display will flash

TIME’S-UP. The tone will sound for one

minute and then turn off automatically to

preserve battery life. To turn the audible

alarm off manually, press any button.

At zero the timer begins timing up. This

feature displays the amount of time which

has elapsed since zero. When the alarm

is sounding, the first press of any button

turns off the electronic tone and stops

the UP timing. Press RESET to clear the

display. The timer will only clear when time

is stopped.

CORRECTING AN ENTRY

If an error is made during an entry, press the

RESET button to clear the display to zero. If

you wish to clear an entry when time is running,

you must first stop the timing by pressing the

STOP button, then press the RESET button.

The timer will only clear when time is stopped.

MEMORY FUNCTION

When timing repetitive intervals, the memory

function will recall the last programmed

time. It allows the user to dedicate the timer

to a frequently timed test. The timer will return

to the desired time period again and again.

Set a programmed time. Press START. When

the alarm sounds, press any button to stop

the tone from sounding and to stop the time.

Press the START button to display the original

programmed time. The display will show

MEMORY TIMER. Press the START button to

begin a memory time.

Advertising