CHECK PLANETARY GEAR OIL LEVEL

Check oil level daily to assure proper lubrication is maintained. Check by removing the fill

plug - with the drive unit standing vertically. Oil should just cover the visible gear.

CHECK FOR CLEAN HYDRAULIC OIL

The majority of all hydraulic component failures are caused by contamination of the

hydraulic oil. At all times, keep dirt and other contaminates from entering the hydraulic

system during connecting and disconnecting the hydraulic system. Always use dust caps

and plugs on all quick disconnects when not in use.

CHECK ALL HYDRAULIC HOSE ASSEMBLIES

Check for cracked or brittle hoses. Replace hoses immediately if cracked or brittle.

Replacement of hoses before failure will prevent loss of hydraulic oil, hydraulic oil

contamination, and component damage caused by cavitation.

CHECK DRIVE UNIT AND ALL ACCESSORIES

Check for loose, bent, cracked, or worn bolts and fasteners. Check drive unit output spindle

for bends, cracks, breaks, or wear. Replace the bolts, fasteners, or output spindle if any of

these conditions exist.

CHECK AUGER

Check for loose or worn cutting teeth and point. Worn teeth or point can dramatically affect

auger penetration and greatly reduce the life of the auger. Always keep spare teeth and

points on hand. Liberally coat the auger with grease once the paint is removed to prevent

rusting.

CHECK ALL CONNECTING PINS

Check for bends, cracks, breaks, or wear. Replace if any of these conditions exist.

COAT THE INSIDE DIAMETER OF THE AUGER OR EXTENSION COLLAR

To prevent rust and reduce wear, liberally coat with grease the inside diameter of the auger

and extension collars each time they are attached.

CHANGE OIL

Change planetary gear reduction oil after first 50 hours of operation, then every 1000 hours

or 12 months, whichever comes first. Use heavy duty extreme pressure lubricant API-GL-5

85W-140 for filling the planetary gear reduction. Approximate oil capacity is two pints (.95

liters).